PR Series Switcher Firmware
Software / Firmware Update
Table of Contents
Brands:
- AMX
Models:
Product Name:
- PR-0402
- PR-0404
- PR-0602
- PR-0808
SKU / FG #:
- AMX-PR-0402
- AMX-PR-0404
- AMX-PR-0602
- AMX-PR-0808
Downloads:
Version: 2.23
Release Date: 3-11-2026
AMX-PR-0402 Firmware
Programming Information:
- Firmware Upgrade through WebGUI
- The system will be non-operational during the upgrade procedure below.
- In the Switcher Configuration menu, enter the “System” page and then click “Browse” in the Firmware Update Column to open the file selection window.
- Select the appropriate KIT file from the target directory.
- Click “Update” to start firmware upgrading. The “Power” LED turns RED and keeps flashing.
- Once the "Power" LED turns GREEN and stop flashing, the unit finishes upgrading and auto reboots to active.
- The system will be non-operational during the upgrade procedure below.
- Firmware Upgrade through USB
- The system will be non-operational during the upgrade procedure below.
- Copy firmware file to folder in USB original disk
- Insert USB Disk to USB Type A program port
- Press "reset" button on the rear panel 5 times in a row, and the unit starts upgrading when the “Power” LED turns RED
and keeps flashing. - Once the "Power" LED turns GREEN and stop flashing, the unit finishes upgrading and auto reboots to active.
- The system will be non-operational during the upgrade procedure below.
Prerequisites:
- None
Known Issues:
Revision History:
- Version 2.23
- Improved WebGUI reliability by preventing system temp file cleanup from disabling web control
functionality over time.
- Improved WebGUI reliability by preventing system temp file cleanup from disabling web control
- Version 2.22
- Added unsolicited feedback for vidin signal status for connect/disconnect activity (or wake/sleep)
- eg. Plugging in a valid signal on input 1 would produce the response:
- >get valid signal on input 1
- Removing the signal on input 1 would produce the response:
- >get no signal on input 1
- Added NEW command/query "get vidin status: <input>" where <input> is the input number
- Added some system settings/status feedback in serial connection on startup (ie. standby, edid, cec, vidin status)
- Added unsolicited feedback for vidin signal status for connect/disconnect activity (or wake/sleep)
- Version 2.20
- Corrected memory issue leading to system lockup over time
- Modified API command response to "vidin portname" to remove "get" from the beginning of the response
- eg. >get vidin portname:1
- was get input port 1 named as ROKU
- is input port 1 named as ROKU
- eg. >get vidin portname:1
- Version 2.18
- Fixed firmware Upgrade Web UI issue.
- Fixed can't SSH to WP after upgrade to V2.1x/2.0x firmware issue.
- Fixed CEC control unavailable issue.
- Fixed LDAP/S feature fail issue.
- Fixed webGUI [IEEE 802.1x Authentication] check box issue.
- Revised username & password from admin:admin to administrator:password
- Fixed Config saving issue->need to remove "Certificate Directory" in case that upload would fail.
- Fixed command typos.
- Fixed Certificate with password reported "Update wrong password" issue.
- Fixed Telnet/SSH few setting commands feedback "incorrect parameter" issue.
- Fixed LDAP error that username can't use space.
- Fixed User Query Attr default would be "uid" issue.
- Fixed LDAP user name character numbers issue.
- Fixed Web GUI login timeout issue
- Fixed Web GUI LDAP setting issue that revision would not be saved.
- Revised ssh account password default to admin:admin.
- Revised web description.
- Fixed CEC manual power on/off function.
- Added LDAPS & 802.1x functions.
- Version 1.55
- Fixed the issue: SSH cannot get corresponding message after telnet turns from off to on.
- Fixed the issue: the unit cannot get the domain name and DNS information from DHCP server.
- Fixed the command feedback typos.
- Fixed the Set commands issue - If no input data, it will keep current parameter.
- Adjusted the OSD position to prevent the OSD from being cut off in overscan screen.
- Changed the EDID library to avoid HDMI source sending unexpected solution.
- Changed the 'HDCP OFF' on OSD to be ‘NO HDCP’
- Added IPv6 API commands.
- Made OSD position adjustable.
- Options: Top Right,Top Left, Bottom Right, Bottom Left and Center
- Took out the System/Network/Security Commands on serial port.
- Added command feedback for "incorrect command" and “incorrect parameter”
- Added 60 seconds timeout for indirect control APIs.