Anytime Help Center

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Support
  • Guest
  • Log In
English (US)
US English (US)
DE German
CN Chinese
MX Spanish (Mexico)
Chinese (Simplified)
  • AKG
    Microphones Wireless Integrated Systems Automatic Mixers Headphones Discontinued Products (AKG) General AKG Inquiries Certifications (AKG)
  • AMX
    Networked A/V Distribution (AVoIP) Traditional A/V Distribution Video Signal Processing Architectural Connectivity User Interfaces Control Processing Power (AMX) Programming (AMX) Software (AMX) Discontinued Products (AMX) General AMX Inquiries Certifications (AMX)
  • BSS
    Soundweb™ Omni Soundweb™ London Soundweb™ Contrio™ Software (BSS) Discontinued Products (BSS) General BSS Inquiries Certifications (BSS)
  • Crown
    CDi DriveCore Series CDi Series Commercial Series ComTech Series DCi DriveCore Series I-Tech HD Series XLC series XLi Series XLS DriveCore 2 Series XTi 2 Series Discontinued Products (Crown) Software (Crown) General Crown Inquiries Certifications (Crown)
  • dbx
    CX Series 500 Series DriveRack Personal Monitor Control ZonePRO Zone Controllers FeedBack Suppression Microphone Preamps Dynamics Processors Crossovers Equalizers Software (dbx) Discontinued Products (dbx) General dbx Inquiries Certifications (dbx)
  • Flux::
    Immersive Processing Analysis Subscriptions General FLUX: Inquiries
  • JBL
    Cinema Sound Installed Live Portable Tour Sound Recording & Broadcast Software (JBL) Discontinued Products (JBL) Video Manual Series (JBL) General JBL Inquiries Certifications (JBL)
  • Lexicon
    Plugins Effects Processors Cinema Discontinued Products (Lexicon) Video Manual Series (Lexicon) General Lexicon Inquiries Certifications (Lexicon)
  • Martin
    Atomic ELP ERA Exterior MAC P3 VC VDO Tools Discontinued Products (Martin) General Martin Inquiries Certifications (Martin)
  • Soundcraft
    Digital Analog Connected Analog Only Discontinued Products (Soundcraft) Video Manual Series (Soundcraft) General Soundcraft Inquiries Certifications (Soundcraft)
  • General HARMAN Inquiries
    Dante
+ More
  • Home
  • AMX
  • Control Processing
  • Central Controllers
  • NX-Series Controllers

NX Master Firmware

Written by Will Fraser

Updated at February 10th, 2026

Table of Contents

Brands: Models: Downloads: Programming Information Prerequisites Revision History Known Issues

Brands:

  • AMX

Models:

Product Name:

  • Master Controllers
    • NX-1200
    • NX-2200
    • NX-3200
    • NX-4200 
  • Enova DVX-x2xx
  • Enova DGX 8/16/32/64
  • Massio Control Pads MCP-10x
  • Enova DGX 800/1600/3200/6400
  • DVXC DVX-2265/3266

SKU / FG #:

FG2106-01 FG2106-02 FG2106-03 FG2106-04 FG1901-16
FG1906-07 FG1906-09 FG1906-11 FG1906-12 FG1906-13
FG1906-14 FG1906-15 FG1906-16 FG1906-17 FG1906-18
FG1906-22 FG1060-08 FG1060-32 FG1060-64  FG2102-06L-B
FG2102-06L-W FG2102-06P-B FG2102-06P-W FG2102-08-B FG2102-08-W
FG1061-08 FG1061-16 FG1061-32 FG1061-64 FG1906-0201
FG1906-0202 FG1906-0401 FG1906-0402    

Downloads:

SW2106_NX-X200_Controller_v1_8_216.zip

 

Previous Build:

SW2106_NX-X200_Master_v1_4_90.zip


Programming Information

  • Use of these new Authentication keywords requires Netlinx.axi v1.62.
  • The NetLinx language supports the following new Authentication keywords:
    • TLS_CLIENT_CLOSE
    • TLS_CLIENT_OPEN
  • For details on the new keywords, please see the NetLinx Language Reference Guide.

Prerequisites

  • When upgrading from 1.3.106 or earlier, you must first upgrade to 1.4.90.

Revision History

  • v1.8.216
    • Fixed issue causing IP for DVX4k to not show up in the Online Tree
  • v1.8.215
    •  Fixed issue causing an NX controller to lockup if the free memory dropped below a certain threshold
  • v1.8.213
    •  Reinstated a previous fix from 1.8.205 for improved memory usage that was unintentionally left out of 1.8.206
    •  Added feature so that "SDAuditLog on/off" works without reboot & updated command help to remove ‘(requires reboot)’
  • v1.8.211
    •  Fixed audit log issue so that after using "clear audit" the audit logging will continue
    •  Updated description to "SDAuditLog on" command to indicate a reboot is required to start logging
    •    (note: this is being changed in the next release to not require reboot)
  • v1.8.210
    •  Corrected LDAP-authenticated users roles to allow execution of certain SSH CLI commands related to device security and logging
  • v1.8.209
    •  Fixed issue causing an NX controller to lockup over time if there were unreachable url in its URL list
  • v1.8.207
    •  Improved ssh_client open/close issues
    •  Improved duplicate ssh keys on NX to be unique on each unit
  • v1.8.206
    •  Fixed issue to allow for pre-connection closure of socket without causing soft rebbot
  • v1.8.205
    •  Improved SSH_CLIENT_OPEN memory usage 
  • v1.8.203
    •  Modified JVM statup parameters to prevent Web Server crash due to java.lang.StackOverflowError
    •  reset factory needed for new defaults to take effect
  • v1.8.202
    •  Added a check for possible issues that could cause the hs_err_pid412
  • v1.8.201
    •  Added TLS_CLIENT_OPEN to support TLSv1.3
  • v1.8.200 
    •  Improved memory usage on Netlinx programs
  • v1.8.197  
    •  Fixed a bug with certificate loading on v1.8.195
  • v1.8.196
    •  Fixed bug causing no OFFLINE event when calling IP_CLIENT_CLOSE 
  • v1.8.195  
    •   upgrade openssh to “SSH-2.0-OpenSSH_9.8”
  • v1.8.193  
    •   Fixed bug with URL entry when using port 1320
  • v1.8.192
    •   Fixed SSH_CLIENT_OPEN/CLOSE bug
  • v1.8.190 (Release)
    •  Fixed boot issue in manufacturing when using blank MSOM with 1.8.x firmware
  • v1.8.187
    •   Added Telnet support for upper case icsp commands: SEND_STRING, SEND STRING, SEND_LEVEL, SEND LEVEL, SEND_COMMAND, SEND COMMAND
  • v1.8.186 
    •   Fixed icsp TLS issue connections with Controller-to-Controller and Controller-to-Panel scenarios
  • v1.8.184 
    •   upgrade TLSv1_2 to TLSv1_3 
  • v1.8.183 (Release)
    •   Added support for new DXLink 4K60 DWP TX in Webgui of DGX and DVX4k
    •   Improved boot time to be faster (except for High Security Mode which takes a few minutes longer due to security key creation and authentication)
    •   Fixed issue with telnet URL list commands causing telnet session to lock up when deleting URL item
    •   Fixed static ip gateway persistence issue during upgrade from 1.6.x to 1.8.x firmware
    •   Fixed telnet Master to Master issue

Known Issues

  • The update should take about 5 minutes after the firmware transfer has completed. If after 5 minutes you can refresh the online tree and still see the old version of firmware, then power cycle the unit to initiate/complete the update. If refreshing the online tree fails to contact the processor, please give the process a few more minutes to complete.
  • If upgrading from 1.6 firmware, wpa_supplicant updates will need to be re-done
  • The following RMS SDKs are not compatible with 1.5.68 and higher: RMS SDK 4.0-4.3.26, RMS SDK 4.4.* and RMS SDK 4.5.*
  • When changing between the local and remote directories for user authentication, the master requires a reboot to force all currently logged in users to re-authenticate with the new service.
  • SSH Key algorithm supports only ssh-rsa host key.
  • ICSPMon will not work with port authentication on or telnet disabled.
  • The USB host ports do not support USB hubs.
  • Performing a PING to the NX master's IPv6 address may cause the NX master to reboot.
  • Master web page login may get stuck in MS-IE browser on Windows8. Either use a different browser or in Internet Options->Advanced->Security Settings check "Enable Enhanced Protection Mode*" (Windows8 restart required).
  • Dynamic images and listview features require v.1.4.9 G5 touch panel firmware if NX security is enabled.
  • Dynamic images  will not work with G4 touch panels with NX security enabled.
  • IP_MC_SERVER_OPEN command does not work on the ICSLan port.
  • The DVX-x2xx Switcher (5002) requires firmware v1.7.54 or higher if authentication is enabled for AMX devices on ICSLAN or LAN Ports.
  • The DGX Switcher (5002) requires firmware v3.2.10 or higher if authentication is enabled for AMX devices on ICSLAN or LAN Ports.

Related Videos

update upgrade

Was this article helpful?

Yes
No
Give feedback about this article

Table of Contents

Brands: Models: Downloads: Programming Information Prerequisites Revision History Known Issues

Related Articles

  • How to discover processor IP if unknown
  • NX USB Filesystem Support
  • Changing the ICSP Port
  • Chip Shortage for RS-422 & 485
  • OpenSSH Vulnerability CVE-2023-38408

Related Articles

  • How to discover processor IP if unknown
  • NX USB Filesystem Support
  • Changing the ICSP Port
  • Chip Shortage for RS-422 & 485
  • OpenSSH Vulnerability CVE-2023-38408