Anytime Help Center

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Support
  • Guest
  • Log In
English (US)
US English (US)
DE German
CN Chinese
MX Spanish (Mexico)
Chinese (Simplified)
  • AKG
    Microphones Wireless Integrated Systems Automatic Mixers Headphones Discontinued Products (AKG) General AKG Inquiries Certifications (AKG)
  • AMX
    Networked A/V Distribution (AVoIP) Traditional A/V Distribution Video Signal Processing Architectural Connectivity User Interfaces Control Processing Power (AMX) Programming (AMX) Software (AMX) Discontinued Products (AMX) General AMX Inquiries Certifications (AMX)
  • BSS
    Soundweb™ Omni Soundweb™ London Soundweb™ Contrio™ Software (BSS) Discontinued Products (BSS) General BSS Inquiries Certifications (BSS)
  • Crown
    CDi DriveCore Series CDi Series Commercial Series ComTech Series DCi DriveCore Series I-Tech HD Series XLC series XLi Series XLS DriveCore 2 Series XTi 2 Series Discontinued Products (Crown) Software (Crown) General Crown Inquiries Certifications (Crown)
  • dbx
    CX Series 500 Series DriveRack Personal Monitor Control ZonePRO Zone Controllers FeedBack Suppression Microphone Preamps Dynamics Processors Crossovers Equalizers Software (dbx) Discontinued Products (dbx) General dbx Inquiries Certifications (dbx)
  • Flux::
    Immersive Processing Analysis Subscriptions
  • JBL
    Cinema Sound Installed Live Portable Tour Sound Recording & Broadcast Software (JBL) Discontinued Products (JBL) Video Manual Series (JBL) General JBL Inquiries Certifications (JBL)
  • Lexicon
    Plugins Effects Processors Cinema Discontinued Products (Lexicon) Video Manual Series (Lexicon) General Lexicon Inquiries Certifications (Lexicon)
  • Martin
    Atomic ELP ERA Exterior MAC P3 VC VDO Tools Discontinued Products (Martin) General Martin Inquiries Certifications (Martin)
  • Soundcraft
    Digital Analog Connected Analog Only Discontinued Products (Soundcraft) Video Manual Series (Soundcraft) General Soundcraft Inquiries Certifications (Soundcraft)
  • General HARMAN Inquiries
    Dante
+ More
  • Home
  • AMX
  • Traditional A/V Distribution
  • Modular Switching Systems
  • Enclosures with Central Controllers

DGX_Config_Software_v1-0-6

Written by Will Fraser

Updated at February 9th, 2026

Table of Contents

Brands: Models: Downloads: Software Notes​: What's New in this release? Installation: Administrator Access and Windows: Dependencies: System Requirements: Distribution Directory Tree Running DGX Configuration Software Uninstalling DGX Configuration Software Known Issues Windows 11 Installation​: Important! Note:

Brands:

  • AMX

Models:

Product Name:

  • DGX-8/16/32/64

Downloads:

Version: v1.0.6
Release Date: 03/04/2014
Download Link:

DGX_Config_Software_v1.0.6.zip


Software Notes​:

What's New in this release?

This is a patch release of this software.

New features include:

  • Support for the DXLF Tx and IO boards.

Installation:

The installer for DGX Configuration Software 1.0 uses Java technology.  We supply an installer that has Java included, which it will install on your PC.  
This is available through the DGX Configuration Software 1.0 Web Site (http://www.amx.com/).    
++ Note that the JVM will NOT be left on your PC after installation!  It is only installed into a temporary folder for the purposes of completing the installation process, then it is removed.

Administrator Access and Windows:

  • You will need admin rights to install this application.  

Dependencies:

Copies of all dependent libraries are installed by default into the WINDOWS\System32 folder.  If you already have one of the dependent dlls in your system PATH environment variable, then the installer will utilize that location for the installation of that specific dll. An additional copy is supplied in the lib subfolder of the InstallFolder in the event you mangle the installed copy somehow. Backups of the current installed dlls can be found in the 'backup' subfolder.  

DGX Configuration Software requires the wpcap 4.1.1 open source library (http://www.winpcap.org/)  The installer will install this if it does not already 
exist on the target PC.

System Requirements:

  • Operating System - Windows XP or 7 Professional is required.
  • Minimum Hardware - 166 MHz, 128 MB RAM, 20 MB free disk space, 800x600 display, USB port with APBridge installed.
  • Recommended Hardware - 2.0 GHz, 512 MB RAM, 20 MB free disk space, 1024x768 display, USB port with APBridge installed.

Distribution Directory Tree

The following files and folder structure are installed:

InstallFolder
    license.html
    DGX Configuration SoftwareReadMe_1_0_6.txt
    Uninstall.exe
    DGX_Config_Software.ico.ico
    ReadMe.ico
     backup (possible if any required DLLs already exist on your system.)
    bin
        DGX_Config_Software.exe
        EDIDProgrammer.exe
        DGX_Cfg_SW.chm.chm
        EDIDProgrammer.GID
        EDIDprogrammer.hlp
        mfc90.dll
        Microsoft.VC90.CRT.manifest
        msvcp90.dll
        msvcr90.dll
        Microsoft.VC90.MFC.manifest
    JExpress
        META-INF
            Manifest.mf
        specmenu
        specreg
        uninstall
        Uninstall.properties
        version.txt
        WinCmds.exe
    depends
        DDCHelper.dll
        ddcdrv.sys
        FactoryDefault_EDIDs
    wpcapInstallers
        ReadMe.txt
        WinPcap_2_3.exe
        4.1.1-WinPcap.exe
    utility
        ReadMe.txt
        wpcapinit.bat
    timings
        CEAtimings.tim
        CVTTimings.tim
        CVTRBTimings.tim
        GTFtimings.tim
        standardtimings.tim

Running DGX Configuration Software

The installer will create a shortcut to DGX Configuration Software on the Start menu. Look for:

Start
    Programs
        AutoPatch Applications
            DGX Configuration Software1.0
                DGX Configuration Software

You can also shell launch (Double click) on DGX_Config_Software.exe directly found in the bin sub folder of the installation.  You can create shortcuts to DGX_Config_Software.exe as is convenient.

If you have any problems running or installing DGX Configuration Software1.0, you can, as always, contact Technical Support at +1 844-776-4899 or through our website at www.amx.com

 Uninstalling DGX Configuration Software

Use the shortcut on Start > Programs > AutoPatch Applications > DGX Configuration Software1.0 > 'Uninstall DGX Configuration Software', OR run Uninstall.exe found in the InstallFolder, OR use the Windows 'Add/Remove Programs' interface in the control pane.  The Wpcap library must be uninstalled manually using the Windows 'Add/Remove Programs' interface.  

Data about your system (connection information, view preferences, etc) will be left in your registry at 
HKEY_CURRENT_USER\Software\XN Technologies\DGX Configuration Software.  If you choose, you can manually delete the DGX Configuration Software key.

Known Issues

  • 64-bit Windows
  • EDIDProgrammer Classic will not function in 64-bit versions of Windows. All other functionality should be unaffected.​

Windows 11 Installation​:
 

Important!

Administrator rights are required to install the application.

 

There are 3 parts to install, all located in the ​DGX_Config_Software_v1-0-6 download.

  • WinPcap.exe
  • ​DGX_Config_Software.exe​
  • APBridge.inf
  • Download the DGX_Config_Software_v1-0-6 located under Downloads in the side bar.
  • Unzip the file.
  • Before performing installation, change the compatibility for WinPcap.exe and DGX_Config_Software_v1-0-6.
  • Set to compatibility to Windows 7 and set to Run as administrator. (Right-click on the file and select Properties.)Compatibility Mode.png

  • Proceed with installation in the following order:
  1. ​WinPcap.exe
  2. DGX_Config_Software.exe​
  3. APBridge.inf (right-click the file and select Install)
  • All set! Start up the DGX Configuration Software. The software will throw a prompt about being Unable to secure Serial Port1. Click OK.  The software will always try to establish a connection upon startup.
  • Instructions for the DGX Configuration Software is located in the EnovaDGX_8_16_32_64 Instruction Manual, appendix A, page 189. The document is available for download under Downloads in the side bar.​

Note:

APBridge​ is a driver for USB connection. It creates a COM port when connected to either of the DGX USB Mini ports. Access to the switcher is through the Control ports or the ENC (RJ-45 ) ports.

 


 

 

Related Videos

upgrade patch

Was this article helpful?

Yes
No
Give feedback about this article

Table of Contents

Brands: Models: Downloads: Software Notes​: What's New in this release? Installation: Administrator Access and Windows: Dependencies: System Requirements: Distribution Directory Tree Running DGX Configuration Software Uninstalling DGX Configuration Software Known Issues Windows 11 Installation​: Important! Note:

Related Articles

  • DGX Endpoint with no Power
  • Displaying a Logo on Input with No Signal on DGX
  • DGX Audio Switching Board Part Numbers
  • DGX 100 series 1.6.x firmware
  • Enova DGX Dante Audio Switching Board Kit Update

Related Articles

  • DGX Endpoint with no Power
  • Displaying a Logo on Input with No Signal on DGX
  • DGX Audio Switching Board Part Numbers
  • DGX 100 series 1.6.x firmware
  • Enova DGX Dante Audio Switching Board Kit Update
Copyright © HARMAN Professional. All rights reserved. Privacy Policy | Terms of Use
Expand