Intermittent Network Loss on Precis Switchers
Escalation Article
Written by Andras Bagoly
Updated at November 17th, 2026
Brand:
- AMX
Affected Products:
- AMX-PR-0402
- AMX-PR-0404
- AMX-PR-0602
- AMX-PR-0808
Summary:
Multiple reports shows of Precis switchers becoming unreachable on the network over time. In affected cases, units configured with a static IP address revert to DHCP after a power cycle. One report also indicated the loss of additional settings, including input labels.
Troubleshooting:
This issue was resolved with new firmware v2.20. or newer.
If the procedure above did not resolve your issue, please contact HARMAN Support for next steps.