Muse Reset
Frequently Asked Questions
Brand:
- AMX
Models:
- MUSE
Question:
Can I reset a Muse controller using the ID button?
Answer:
YES.
The ID Pushbutton functionality is as follows:
| ID Button Hold Duration | Status LED color | Function Performed on Release |
| Not held | Green, blinking if scripts are running | Running normally |
| 0 – 10 seconds | White, fast blinking | Running normally, ID broadcast sent |
| 10 – 20 seconds | Amber, fast blinking | Configuration Reset (see below) |
| 20 + seconds | Red, fast blinking | Factory Firmware Reset (see below) |
A configuration reset performs the following operations:
- All user scripts (Python, Groovy, JavaScript and Node-RED) and libraries are deleted
- All manually installed extensions are uninstalled
- All manually configured repositories are removed
- All device instance files are removed
- All Plug-in configuration items are reset to their defaults
- All SMTP servers are removed
- ICSP authentication/encryption returns to "off"
- All bound NDP devices are unbound (TBD)
- All IRL files are removed
- All installed HiQnet AudioArchitect files are removed
- HiQnet node id returns to default
- All Duet module .jar files are removed
- Network configuration is returned to defaults
- LAN returns to DHCP client mode, hostname returns default value
- ICSLan returns to DHCP Server mode on octets 198.18.0.x
- 802.1x is disabled
- Network time is disabled
- NTP servers are cleared
- Time will coast using the real-time clock
- Time zone returns to default
- User accounts are deleted
- The default credentials of "admin" with default "password" are restored • "support" user is disabled
- Any configured syslog server is disabled and cleared
- Any configured flash media logging is disabled
- Any manually installed certificates are removed
- Factory certificates for HControl, HTTPS and Secure ICSP are restored
- Device control ports return to default state
- IRL files are cleared
- Serial port comm parameters return to their default (9600, 8 data bits, 1 stop bit, No parity, 422/485 disabled)
- All I/O's return to digital input mode with default threshold values
A Factory Firmware reset includes a Configuration Reset and also loads the original firmware present at the time of manufacture.