Anytime Help Center

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Support
  • Guest
  • Log In
English (US)
US English (US)
DE German
CN Chinese
MX Spanish (Mexico)
Chinese (Simplified)
  • AKG
    Microphones Wireless Integrated Systems Automatic Mixers Headphones Discontinued Products (AKG) General AKG Inquiries Certifications (AKG)
  • AMX
    Networked A/V Distribution (AVoIP) Traditional A/V Distribution Video Signal Processing Architectural Connectivity User Interfaces Control Processing Power (AMX) Programming (AMX) Software (AMX) Discontinued Products (AMX) General AMX Inquiries Certifications (AMX)
  • BSS
    Soundweb™ Omni Soundweb™ London Soundweb™ Contrio™ Software (BSS) Discontinued Products (BSS) General BSS Inquiries Certifications (BSS)
  • Crown
    CDi DriveCore Series CDi Series Commercial Series ComTech Series DCi DriveCore Series I-Tech HD Series XLC series XLi Series XLS DriveCore 2 Series XTi 2 Series Discontinued Products (Crown) Software (Crown) General Crown Inquiries Certifications (Crown)
  • dbx
    CX Series 500 Series DriveRack Personal Monitor Control ZonePRO Zone Controllers FeedBack Suppression Microphone Preamps Dynamics Processors Crossovers Equalizers Software (dbx) Discontinued Products (dbx) General dbx Inquiries Certifications (dbx)
  • Flux::
    Immersive Processing Analysis Subscriptions
  • JBL
    Cinema Sound Installed Live Portable Tour Sound Recording & Broadcast Software (JBL) Discontinued Products (JBL) Video Manual Series (JBL) General JBL Inquiries Certifications (JBL)
  • Lexicon
    Plugins Effects Processors Cinema Discontinued Products (Lexicon) Video Manual Series (Lexicon) General Lexicon Inquiries Certifications (Lexicon)
  • Martin
    Atomic ELP ERA Exterior MAC P3 VC VDO Tools Discontinued Products (Martin) General Martin Inquiries Certifications (Martin)
  • Soundcraft
    Digital Analog Connected Analog Only Discontinued Products (Soundcraft) Video Manual Series (Soundcraft) General Soundcraft Inquiries Certifications (Soundcraft)
  • General HARMAN Inquiries
    Dante
+ More
  • Home
  • AMX
  • Traditional A/V Distribution
  • Modular Switching Systems
  • Enclosures with Central Controllers

Enova DGX Switcher Hotfix

Technical Support Guide

Written by Peter Stauber

Updated at January 27th, 2026

Table of Contents

Enova DGX Switcher Hotfix Downloads:

Enova DGX Switcher Hotfix

Enova DGX Firmware
Version 2.0.6 Standard DGX – Pre_X00 series

Firmware Notes:
Product Name: Enova DGX 8/16/32/64 Enclosures

 

=========== ======================  ======================

FG #        Name                           Description

=========== ======================  ======================

FG1058-08   AVS-ENOVADGX8-ENC       Enova DGX 8 Enclosure

FG1058-16   AVS-ENOVADGX16-ENC      Enova DGX 16 Enclosure

FG1059-32   AVS-ENOVADGX32-ENC      Enova DGX 32 Enclosure

FG1059-33   AVS-ENOVADGX32-ENC-A    Enova DGX 32 Enclosure

FG1060-08   DGX8-ENC                         Enova DGX 8 Enclosure

FG1060-16   DGX16-ENC                       Enova DGX 16 Enclosure

FG1060-32   DGX32-ENC-A                    Enova DGX 32 Enclosure

FG1060-64   DGX64-ENC                       Enova DGX 64 Enclosure

 

 

*****************IMPORTANT********************************

If sending this kit to a DGX 8/16/32 with

v1.6.5.13 (or earlier), you MUST FIRST send

the following kit to the Enova DGX enclosure:

"LOAD_BEFORE_SENDING_DGX_KIT.kit"

(This takes around 1 minute to complete)

**********************************************************

 

 

IMPORTANT NOTE ABOUT TIME REQUIRED TO UPGRADE:

 See the Programming Information section in this

 read me for an explanation of how to know when

 the upgrade is complete as well as estimates of

 the time required for the update to successfully

 upgrade.  Ignoring this information could cause

 your upgrade to fail to complete.

 

 

 

Current Firmware Version: 2.0.6

Build Date: 2017-09-22

 

Website Availability: EnovaDGX_2.0.6.kit

Device Id: 5002

 

EnovaDGX KIT file 2.0.6 contains these firmware images:

 

* Indicates changes since v2.0.4

 

- MCPU 8 NI-Series          v2.6.2.2

- MCPU 16 NI-Series         v2.6.2.2

- MCPU 32 NI-Series         v2.6.2.2

- MCPU 8 NX-Series          v2.8.2.4

- MCPU 16 NX-Series         v2.8.2.4

- MCPU 32 NX-Series         v2.8.2.4

- MCPU 64 NX-Series         v2.8.2.4

- Power BCPU 8 NI-Series    v2.2.2.1

- Power BCPU 16 NI-Series   v2.2.2.1

- Power BCPU 32 NI-Series   v2.2.2.1

- Power BCPU Nx-Series      v2.4.1.6

- DGX Center Board          v2.0.2.3

- SC Fiber Input            v2.0.0.6

- SC Fiber Output           v2.0.1.2

- DVI/HDMI Input            v1.0.8.1

- DVI/HDMI Output           v1.2.6.2

- DXLink Input              v1.2.5.1*

- DXLink Output             v1.2.3.2*

- DGX AIE Board             v1.0.0.4

- DGX64 AIE Board           v2.0.1.1

- 6p switch                 v1.0.2.1

- 24p Config                v1.2.1.1

- 24p ext Board             v1.0.0.2

- DXLink Rx FW              v3.0.6.0

- DXLink Tx FW              v3.0.6.0

- DXLink Fiber Fw           v1.0.1.4

- Output Scaler             v1.8

- SRM File                  v1.0.5.1

 

- Integrated App            v1.2.1.15

 

 

 

 

----------------------------------------------------------

Prerequisites

----------------------------------------------------------

- SW1058_Master_v4_2_395.KIT (NI-Series) or later must be

 loaded on the Master before this KIT file can be loaded

 for Enova DGX 8/16/32 MCPU v2.6.x.x or earlier boards.

 Shows in Online Tree as "NI Master"

 

- SW1060_Master_v1_3_106.KIT (NX-Series) or later must be

 loaded on the master for the Enova DGX 8/16/32/64

 MCPU v2.8.x.x boards. Shows in Sutdio as "DGX Master"

 

- NetLinx Studio v4.0 is required to work with the

 NX-Series DGX Masters.

 

 

----------------------------------------------------------

Note: Endpoint firmware should NOT exceed the following

versions whenever when using DGX FW version 2.0.x/2.0.2.2:

- DXLink DX-TX v1.6.x

- DXLink DX-RX v1.9.x

- DXLink DXF-TX v1.2.12

- DXLink DXF-RX v1.2.1

 

----------------------------------------------------------

Changes in this release

----------------------------------------------------------

DXLink Input

- Updated firmware to support alternate flash memory parts

  NOTE: Boards using these new parts will not function with

  firmware earlier than v1.2.5.1 - Do not roll back.

 

DXLink Output

 - Improved ethernet switch monitoring to prevent offline

   issues with RX on system power up

 

----------------------------------------------------------

Known Issues

----------------------------------------------------------

- A wait of 15seconds is required when Hot Swapping DGX

 I/O boards

 

 

- DGX Configuration Software

     The DGX Config Software has not been tested with any

     non-English versions of Windows XP or Windows 7.

 

- DXLink Tx Fw v3.0.6.0

    The 'show stats' DGX Shell command (or “show vs100

    stats" from the DXLINK TX/RX telnet command) may

    report some cable lengths approaching 100m as 255m.

    This is a reporting limitation imposed by the chip mfr

    for TX v3.0.6.0 and does not affect the functionality.

    This applies to any DGX or DVX DXLink output, or any

    DXLink TX/MFTX module or wallplate using this version.

 

- DO NOT USE THE "DGX_SHELL>reboot" command with older

 ENOVA DGX 8/16/32 Enclosures with Power-One Power

 Supplies that have the new CPU with NX-Series Master.

 This WILL cause the cards to not power up and REQUIRE a

 hard power cycle of the cage. Power-One supplies may be

 identified in the ~scr6v3! or with the

 "DGX_SHELL>power INFO" command by model number:

 e.g. model: FNP850-12ARG (Power-One Supply)

 

 

----------------------------------------------------------

Programming Information

----------------------------------------------------------

-  If sending this kit to a DGX 8/16/32 with v1.6.5.13 or

  earlier, you MUST FIRST send the following kit to the

  Enova DGX enclosure: "LOAD_BEFORE_SENDING_DGX_KIT.kit"

  This takes around 1 minute to complete. Once completed,

  refresh the System Online Tree and expand the 5002

  device to verify that the Integrated Device version is

  now at v1.2.1.15 - Then send this DGX kit to complete

  the system upgrade

 

- Upgrade time may take up to 2 hours.

 

- The only reliable way to monitor the upgrade is to jump

 directly to the upgrade status page with the url:

 http://master_ipAddr/web/upgrade/systemUpgradeStatus.xml

 before initiating the KIT upgrade to monitor the runtime

 upgrade status.

 

- It is recommended that you disable any program running

 on the DGX or that you disable any program using the

 Enova DGX BCSTunnel service before initiating the Enova

 DGX KIT firmware upgrade.

 

- It is also recommended that you disconnect/disable any

 control system using the external serial connection(s)

 during any KIT file upgrades.

 

- After the Upgrade Status page has indicated that the

 Enova DGX firmware upgrade was successful and device

 5002 has come back online, it is recommended that you

 power cycle the DGX to insure all endpoint devices come

 back online properly.

 

- New HDMI/DVI Input boards will only work with v1.0.6.4

 image or greater (v2.0.0.10 DGX KIT) or greater due to

 hardware design change. It can be identified in the shell

 “show" command with a hardware ID of 1 (HW_ID 0x1).

 

- New DXLink Fiber Input/Output Simplex Boards will

 not be compatible with v1.2.0.x DXLink images or older.

 Enova DGX KIT v2.0.0.8 or older will fail to load with

 these boards present in the system.  ​


Downloads:

  • EnovaDGX_2.0.6.zip
  • EnovaDGX_2.2.12-1.zip

 

Related Videos

framework model

Was this article helpful?

Yes
No
Give feedback about this article

Table of Contents

Enova DGX Switcher Hotfix Downloads:

Related Articles

  • DGX Endpoint with no Power
  • Displaying a Logo on Input with No Signal on DGX
  • DGX Audio Switching Board Part Numbers
  • DGX 100 series 1.6.x firmware
  • Enova DGX Dante Audio Switching Board Kit Update

Related Articles

  • DGX Endpoint with no Power
  • Displaying a Logo on Input with No Signal on DGX
  • DGX Audio Switching Board Part Numbers
  • DGX 100 series 1.6.x firmware
  • Enova DGX Dante Audio Switching Board Kit Update
Copyright © HARMAN Professional. All rights reserved. Privacy Policy | Terms of Use
Expand