Ui24R: Legacy Consoles Boot Loop on Firmware v3.4 Update
Table of Contents
Brand:
-
Soundcraft
Affected Products:
- Ui24R Digital Mixer
Summary:
- When updating certain legacy Soundcraft Ui24R consoles to firmware v3.4, the unit may fail to complete boot initialization and enter a continuous boot loop, indicated by permanently pulsing Master LEDs. Installing Firmware v3.5 (or higher) resolves compatibility issues on legacy ARM processor hardware revisions.
Troubleshooting:
- End-User Action:
- Download the latest official firmware update (Ui24R Firmware v3.5 or higher) directly from the Soundcraft website or Help Center.
- If an affected console is currently stuck in a boot loop on v3.4, perform a Full Reset / Factory Recovery procedure using an external USB drive loaded with stable firmware (v3.3 or v3.5+).
- Re-apply the update to bring the console to v3.5+.
- Workarounds:
Factory Full Reset Procedure: Execute a full hardware reset using the physical reset pinhole and a FAT32-formatted USB flash drive loaded with working firmware (e.g., v3.3 or v3.5+) to recover stuck units.
- Resolution:
Update console firmware to version v3.5 or higher.
- Verification:
Power cycle the unit following the v3.5 update and verify that the console boots normally into the standard operating UI without LED pulsing.