MUSE MU-XXXX Hotfix Firmware
Table of Contents
Download Links:
MU-XXXX_FW_v1_4_101_Automator-Mac-1.3.17.zip
MU-XXXX_FW_v1_4_101_Automator-Windows-1.3.17.zip
Products:
- MU-1000
- MU-1300
- MU-2300
- MU-3300
FG#:
- AMX-CCC000
- AMX-CCC013
- AMX-CCC023
- AMX-CCC033
Hot Fix Firmware Version:
1.4.101
Release Date:
February 26, 2026
Minimum Software Requirements:
MUSE Automator 1.3.17 : (included in download zip)
VSCode Plug-in 1.5.13 : https://www.amx.com/en-US/products/muse-extension-for-vscode
Programming Information:
Install .SWU file thru MUSE web interface or via USB drive
Changes in current version:
- Resolved: HiQnet issue querying parameter values with active “watch”/subscription
- Resolved: Incorrect failed login attempt reporting
- Resolved: Alert messages stack up and never time out
Changes in 1.4.87:
- Added support for Scopes for devices & scripts
- Moved System>>Devices and System>>Programs web pages content to new System>>Scopes page
- Auth Manager security enhancements required for JITC certification
- HiQnet Protocol Driver improvements
- Node-RED Web Access option re-enabled on the Security page
- This allows access to Node-RED on MUSE at [ip]:1880/red
- This allows access to Dashboard 2.0 support at [ip]:1880/dashboard when using the Dashboard 2.0 palette for a MUSE-hosted HTML5 UI
- Web page rendered in dark mode for consistent branding with other HARMAN Pro product interfaces & software
Changes in 1.3.51:
- Fixed HiQnet device parameter subscription/resubscription, regardless of device boot order or script start order
Changes in 1.3.39:
- System does not work if MUSE is booted before HiQnet devices
Changes in 1.3.34:
- Fix Duet command execution and module/reinitialize
- Disable FIPS by default. Requires reset to factory config if 1.3.32 already installed
Changes in 1.2.69:
- Added passBackEvent support to Duet Driver
- Added dynamic component support to Duet Driver
Changes in 1.2.65:
- Python Upgrade to version 3.10
- Added MUSE Controller-to-Controller support
- Added Scripts as devices support
- Added LDAP Support
- Added Auth Session Service
- Added Python PIP installation through requirements.txt
- Added Platform Service
- Added I/O Manager Support for CE-COM2 devices
- Added ICSLAN DNS lookup support
- Added Security Banner Support
- Added NetLinx Device Client driver
Known Issues:
- TPControl (TPC) apps exhibit an issue with MUSE controllers where erroneous dynamic device IDs are continuously created in addition to the primary device connection.
- 802.1x configuration using TLS or TTLS fails
Other:
- USB drives support FAT32 file system
- TS/ESC reference: HPSD-29517; HPSD-29536; HPSD-29638