Anytime Help Center

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Support
  • Guest
  • Log In
English (US)
US English (US)
DE German
CN Chinese
MX Spanish (Mexico)
Chinese (Simplified)
  • AKG
    Microphones Wireless Integrated Systems Automatic Mixers Headphones Discontinued Products (AKG) General AKG Inquiries Certifications (AKG)
  • AMX
    Networked A/V Distribution (AVoIP) Traditional A/V Distribution Video Signal Processing Architectural Connectivity User Interfaces Control Processing Power (AMX) Programming (AMX) Software (AMX) Discontinued Products (AMX) General AMX Inquiries Certifications (AMX)
  • BSS
    Soundweb™ Omni Soundweb™ London Soundweb™ Contrio™ Software (BSS) Discontinued Products (BSS) General BSS Inquiries Certifications (BSS)
  • Crown
    CDi DriveCore Series CDi Series Commercial Series ComTech Series DCi DriveCore Series I-Tech HD Series XLC series XLi Series XLS DriveCore 2 Series XTi 2 Series Discontinued Products (Crown) Software (Crown) General Crown Inquiries Certifications (Crown)
  • dbx
    CX Series 500 Series DriveRack Personal Monitor Control ZonePRO Zone Controllers FeedBack Suppression Microphone Preamps Dynamics Processors Crossovers Equalizers Software (dbx) Discontinued Products (dbx) General dbx Inquiries Certifications (dbx)
  • Flux::
    Immersive Processing Analysis Subscriptions
  • JBL
    Cinema Sound Installed Live Portable Tour Sound Recording & Broadcast Software (JBL) Discontinued Products (JBL) Video Manual Series (JBL) General JBL Inquiries Certifications (JBL)
  • Lexicon
    Plugins Effects Processors Cinema Discontinued Products (Lexicon) Video Manual Series (Lexicon) General Lexicon Inquiries Certifications (Lexicon)
  • Martin
    Atomic ELP ERA Exterior MAC P3 VC VDO Tools Discontinued Products (Martin) General Martin Inquiries Certifications (Martin)
  • Soundcraft
    Digital Analog Connected Analog Only Discontinued Products (Soundcraft) Video Manual Series (Soundcraft) General Soundcraft Inquiries Certifications (Soundcraft)
  • General HARMAN Inquiries
    Dante
+ More
  • Home
  • BSS
  • Soundweb™ London
  • General London Inquiries

HARMAN HiQnet Communication On A Routed Network

Written by Gary Brindley

Updated at January 27th, 2026

Table of Contents

Introduction Routed Network Discovery Mechanism: Static Routes Configuring Static Routes About Static Routes Routed Network Discovery Mechanism: Crown Proxy Configuring Crown Proxy About Proxy Connections Using Static Routes and Proxy Connections Ports Used by BSS Soundweb London and Soundweb Contrio Devices Ports Used by Crown Devices Ports used by Motion Control Requirements for Audio Architect Discovery of Devices on a Remote Network Capability of Devices to Control a Soundweb London Chassis Device on a Remote Network Functionality Between Soundweb London Devices on Local Remote and Devices on Remote Network

Introduction

BSS Soundweb London devices, Crown devices, Motion Control app and Audio Architect software communicate on an Ethernet network using the HiQnet protocol.  HiQnet devices and software must discover other devices on the network before the exchange of control data can begin.  The device discovery mechanism employs UDP broadcast packets that are transmitted over a switched network but cannot pass across a router.  This guide will outline the two mechanisms by which HiQnet devices and software can discover each other on routed networks.


pic1.bmp

Routed Network Discovery Mechanism: Static Routes

This mechanism allows Audio Architect to discover certain HiQnet devices on a remote network segment by entering their IP addresses manually.  Audio Architect will then be able to communicate and discover the HiQnet device on the remote network segment directly without the need for UDP broadcast packets.
Static Routes can be used for the following devices: BSS Soundweb London, Crown DCi, i Tech, CTs, i OS Motion Control.
Static Routes cannot be used for the following devices: Soundweb Contrio, Crown CDi.


pic2.bmp

Configuring Static Routes

  • Open the File menu and choose Application Options.  Select the Proxies/Static Routes page.
  • Click Add in the Static Routes section.  A new Static Routes entry will appear in the list.
  • Click the entry and enter the IP address of the device on the remote network.
  • Add an entry for each Soundweb London device and each Crown device that supports Static Routes.
  • Click OK, then click Yes in the Static Routes dialogue.

Audio Architect will attempt to discover the devices and list them in the Discovered folder in the Venue Explorer.
Static Routes can be disabled by unticking the box in the Active column.


pic3.bmp

About Static Routes

Static Routes are stored in the file: Static Routes.txt which is located in the folder: C:\Program Data\HPRO\Networking.
The Static Routes.txt file will be updated when Static Routes are configured using Audio Architect, Net Setter or Performance Manager.
The Static Routes.txt file can edited manually and shared between computers.
Applications will not update their list of Static Routes automatically if changes have been made to the Static Routes.txt file manually or with another application.

  • Click on Import to update the list of Static Routes from the Static Routes.txt file.

Routed Network Discovery Mechanism: Crown Proxy

This mechanism allows Audio Architect to discover any HiQnet device on a remote network segment using a single Crown device located on the remote network. The designated Crown device will forward all discovery and control data from the remote network to Audio architect.
The following devices can be employed as a Crown Proxy: Crown DCi, i Tech, CTs

Configuring Crown Proxy

  • Open the File menu and choose Application Options.  Select the Proxies/Static Routes page.
  • Click Add in the Proxy Connections section.  A new Proxy Connection entry will appear in the list.
  • Click the entry and enter the IP address of the Crown device on the remote network.
  • Click OK, then click Yes in the Proxy Connections dialogue.

Audio Architect will attempt to discover the devices and list them in the Discovered folder in the Venue Explorer.
Proxy Connections can be disabled by unticking the box in the Active column.

About Proxy Connections

Proxy Connections are stored in the file: Proxy Connections.txt which is located in the folder: C:\Program Data\HPRO\Networking.
The Proxy Connections.txt file will be updated when Proxy Connections are configured using Audio Architect, Net Setter or Performance Manager.
The Proxy Connections.txt file can edited manually and shared between computers.
Applications will not update their list of Proxy Connections automatically if changes have been made to the Proxy Connections.txt file manually or with another application.

  • Click on Import to update the list of Static Routes from the Proxy Connections.txt file.

Using Static Routes and Proxy Connections

The IP address of the devices on the remote network must not change.  Use static IP address or DHCP Reservation.
The IP address settings of the devices on the remote network must include a Gateway Address.
Ensure that router or VPN connection is not blocking the ports listed below.
If the HiQnet device on the remote network is not discovered then port 3804 TCP is being blocked by router or VPN.
If the Soundweb London device on the remote network is failing to update firmware then port 21 TCP is being blocked by the router or VPN.
If the Crown device on the remote network is failing to update firmware then port 69 UDP is being blocked.

Ports Used by BSS Soundweb London and Soundweb Contrio Devices

3804 TCP & UDP: HiQnet device discovery and communication
21 TCP: FTP for loading Configuration, loading firmware and transferring event logs

Ports Used by Crown Devices

3804 TCP & UDP: HiQnet device discovery and communication
69 UDP: TFTP for loading firmware

Ports used by Motion Control

3804 TCP & UDP: HiQnet device discovery and communication

Requirements for Audio Architect Discovery of Devices on a Remote Network

Soundweb London: Static Route or Crown Proxy
Soundweb Contrio: Crown Proxy
Motion Control i OS app: Static Route or Crown Proxy
Crown DCi, i Tech, CTs: Static Route or Crown Proxy

Capability of Devices to Control a Soundweb London Chassis Device on a Remote Network

Audio Architect software – possible with Static Route or Crown Proxy
Soundweb BLU-8 wall controller – not possible
Soundweb BLU-10 wall controller – not possible
Soundweb Contrio EC wall controller – not possible
Third Party Messages on port 1023 - possible
Motion Control i OS app: possible with Crown Proxy or by entering Soundweb London chassis IP address in Settings/Proxy Address

Functionality Between Soundweb London Devices on Local Remote and Devices on Remote Network

Logic Ethernet Trigger: functional
Audio Links and Logic Links: not functional
Logic Device Monitor: not functional
Logic Preset trigger: not functional

Related Videos

network communication harman

Was this article helpful?

Yes
No
Give feedback about this article

Table of Contents

Introduction Routed Network Discovery Mechanism: Static Routes Configuring Static Routes About Static Routes Routed Network Discovery Mechanism: Crown Proxy Configuring Crown Proxy About Proxy Connections Using Static Routes and Proxy Connections Ports Used by BSS Soundweb London and Soundweb Contrio Devices Ports Used by Crown Devices Ports used by Motion Control Requirements for Audio Architect Discovery of Devices on a Remote Network Capability of Devices to Control a Soundweb London Chassis Device on a Remote Network Functionality Between Soundweb London Devices on Local Remote and Devices on Remote Network

Related Articles

  • Software Used to Configure Soundweb London
  • Accuracy of the Real Time Clock in a BSS Soundweb London Device
  • Using Soundweb London in Dante Domain Manager With AES67
  • BSS Serial Number Location
  • Changing Input Polarity on BSS Soundweb Devices

Related Articles

  • Software Used to Configure Soundweb London
  • Accuracy of the Real Time Clock in a BSS Soundweb London Device
  • Using Soundweb London in Dante Domain Manager With AES67
  • BSS Serial Number Location
  • Changing Input Polarity on BSS Soundweb Devices
Copyright © HARMAN Professional. All rights reserved. Privacy Policy | Terms of Use
Expand