Anytime Help Center

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Support
  • Guest
  • Log In
English (US)
US English (US)
DE German
CN Chinese
MX Spanish (Mexico)
Chinese (Simplified)
  • AKG
    Microphones Wireless Integrated Systems Automatic Mixers Headphones Discontinued Products (AKG) General AKG Inquiries Certifications (AKG)
  • AMX
    Networked A/V Distribution (AVoIP) Traditional A/V Distribution Video Signal Processing Architectural Connectivity User Interfaces Control Processing Power (AMX) Programming (AMX) Software (AMX) Discontinued Products (AMX) General AMX Inquiries Certifications (AMX)
  • BSS
    Soundweb™ Omni Soundweb™ London Soundweb™ Contrio™ Software (BSS) Discontinued Products (BSS) General BSS Inquiries Certifications (BSS)
  • Crown
    CDi DriveCore Series CDi Series Commercial Series ComTech Series DCi DriveCore Series I-Tech HD Series XLC series XLi Series XLS DriveCore 2 Series XTi 2 Series Discontinued Products (Crown) Software (Crown) General Crown Inquiries Certifications (Crown)
  • dbx
    CX Series 500 Series DriveRack Personal Monitor Control ZonePRO Zone Controllers FeedBack Suppression Microphone Preamps Dynamics Processors Crossovers Equalizers Software (dbx) Discontinued Products (dbx) General dbx Inquiries Certifications (dbx)
  • Flux::
    Immersive Processing Analysis Subscriptions General FLUX: Inquiries
  • JBL
    Cinema Sound Installed Live Portable Tour Sound Recording & Broadcast Software (JBL) Discontinued Products (JBL) Video Manual Series (JBL) General JBL Inquiries Certifications (JBL)
  • Lexicon
    Plugins Effects Processors Cinema Discontinued Products (Lexicon) Video Manual Series (Lexicon) General Lexicon Inquiries Certifications (Lexicon)
  • Martin
    Atomic ELP ERA Exterior MAC P3 VC VDO Tools Discontinued Products (Martin) General Martin Inquiries Certifications (Martin)
  • Soundcraft
    Digital Analog Connected Analog Only Discontinued Products (Soundcraft) Video Manual Series (Soundcraft) General Soundcraft Inquiries Certifications (Soundcraft)
  • General HARMAN Inquiries
    Dante
+ More
  • Home
  • Crown
  • DCi DriveCore Series
  • General DCi Drivecore Inquiries

Configuring Continuous Load Monitoring with DCi Amplifiers

Written by Gary Brindley

Updated at February 12th, 2026

​​​How to configure a DCi Network amplifier to monitor and report errors​​ in output load impedance.​

Transcript
DCI amplifiers with network control and ESP have the ability to monitor speaker load impedance and report any faults detected this feature called continuous load monitoring is configured using hiking net audio architect software to enable continuous load monitoring double-click on the virtual representation of the amp to open the default device panel next double click on the amp icon for the output channel you wish to configure to bring up the amplifier settings window the controls for continuous load monitoring are located to the right side of this window first enter the nominal expected impedance of the load next designate the high and low thresholds that will determine when the test is a failure the default values are acceptable when simply trying to detect an open or a short but you may want to narrow the thresholds when connected to a parallel series for series parallel load to help determine individual speaker failures finally turn on continuous load monitoring by pressing the button to the on state when there is enough output signal to obtain an accurate measurement the feature will automatically start testing when measuring the testing indicator will be illuminated in the measured impedance reported if the report errors button is turned on the event log will also indicate that the expected speaker load impedance is outside the low and high threshold the amplifier GPIO can also be configured to toggle states when report errors is turned on additionally the load indicator on the default device panel will light up red this feature is not designed to work during light background music another low amplitude audio signal the amplifier will only begin testing when there is substantial audio on the output channel thank you for watching this video for questions comments or suggestions regarding this or any other video please send them to the email address shown below for technical assistance please call the technical support department or email them at the options shown below.

Related Videos

dc amplifiers load monitoring

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Configuring BLU Link for 48/96kHz with DCi Amplifiers
  • Analog vs Network Comparison with DCi Amplifiers
  • BLU Link Input Routing with DCi Amplifiers

Related Articles

  • Configuring BLU Link for 48/96kHz with DCi Amplifiers
  • Analog vs Network Comparison with DCi Amplifiers
  • BLU Link Input Routing with DCi Amplifiers
Copyright © HARMAN Professional. All rights reserved. Privacy Policy | Terms of Use
Expand