Summary:
On Crown 4x3500HD amplifiers, recalling a preset from the front panel may fail to switch outputs from bridge mode back to dual (unbridged) mode. This can occur after the amplifier has been configured in bridge mode using Audio Architect and then operated without the software running.
Escalation Ticket:
TSC-00463748-ESC001
JIRA Ticket:
HPSD-31482
Problem:
Affected Environment
This issue was confirmed using the current versions of firmware and software as of May 6, 2026.
- Product: Crown 4x3500HD
- Firmware version: v1.0.5.21
- Display version: v2.0.1.2
- Audio Architect 2.55.3
Symptoms
- After recalling a non-bridged preset from the front panel, outputs remain effectively bridged.
- Even-numbered channels display “N/A” on the front panel.
- Front-panel LEDs indicate bridged operation (e.g., only odd channels show a Ready LED).
Expected Behavior
- Recalling a non-bridged preset should return channels to dual mode.
Actual Behavior
- Channels previously bridged do not revert to dual mode when a non-bridged preset is recalled from the front panel.
Solution:
Workaround
- Do not close Audio Architect while the amplifier is set to a preset with bridged outputs.
Recovery
- If the problem has already occurred, perform a factory reset on the amplifier. Then reprogram the amplifier and be sure it is on the default preset or another non-bridged preset before closing Audio Architect.
Status
- This issue has been reproduced and escalated to determine the root cause and address it via a future firmware or software update.