Anytime Help Center

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Support
  • Guest
  • Log In
English (US)
US English (US)
DE German
CN Chinese
MX Spanish (Mexico)
Chinese (Simplified)
  • AKG
    Microphones Wireless Integrated Systems Automatic Mixers Headphones Discontinued Products (AKG) General AKG Inquiries Certifications (AKG)
  • AMX
    Networked A/V Distribution (AVoIP) Traditional A/V Distribution Video Signal Processing Architectural Connectivity User Interfaces Control Processing Power (AMX) Programming (AMX) Software (AMX) Discontinued Products (AMX) General AMX Inquiries Certifications (AMX)
  • BSS
    Soundweb™ Omni Soundweb™ London Soundweb™ Contrio™ Software (BSS) Discontinued Products (BSS) General BSS Inquiries Certifications (BSS)
  • Crown
    CDi DriveCore Series CDi Series Commercial Series ComTech Series DCi DriveCore Series I-Tech HD Series XLC series XLi Series XLS DriveCore 2 Series XTi 2 Series Discontinued Products (Crown) Software (Crown) General Crown Inquiries Certifications (Crown)
  • dbx
    CX Series 500 Series DriveRack Personal Monitor Control ZonePRO Zone Controllers FeedBack Suppression Microphone Preamps Dynamics Processors Crossovers Equalizers Software (dbx) Discontinued Products (dbx) General dbx Inquiries Certifications (dbx)
  • Flux::
    Immersive Processing Analysis Subscriptions General FLUX: Inquiries
  • JBL
    Cinema Sound Installed Live Portable Tour Sound Recording & Broadcast Software (JBL) Discontinued Products (JBL) Video Manual Series (JBL) General JBL Inquiries Certifications (JBL)
  • Lexicon
    Plugins Effects Processors Cinema Discontinued Products (Lexicon) Video Manual Series (Lexicon) General Lexicon Inquiries Certifications (Lexicon)
  • Martin
    Atomic ELP ERA Exterior MAC P3 VC VDO Tools Discontinued Products (Martin) General Martin Inquiries Certifications (Martin)
  • Soundcraft
    Digital Analog Connected Analog Only Discontinued Products (Soundcraft) Video Manual Series (Soundcraft) General Soundcraft Inquiries Certifications (Soundcraft)
  • General HARMAN Inquiries
    Dante
+ More
  • Home
  • AMX
  • Discontinued Products (AMX)

NXR-ZGW

Written by Will Fraser

Updated at February 18th, 2026

Table of Contents

Brands: Models: Downloads: Information: General Notes: CAUTION: Known Issues: Loading procedures:

Brands:

  • AMX

Models:

Product Name:

  • MIO Modero

Downloads:

Version: v3.01.17
Release Date: [mm/dd/yyyy]
Download Link:

SW5791_01A_NXR_ZGW_v3_01_17.zip

Previous Release:

SW5791_01A_NXR_ZGW_v3_01_13.zip


Information:

Changes in 3.01.17

  • Fixes the "auto-release" bug by sending correct system number information
  • Includes zero-config fix
  • Icsp may now use ports other than 1319
  • Includes two new features
        1. May send Netlinx command to Gateway to turn Gateway to "Joinable"
            -- send_command <device>, 'Join'
        2. May send Netlinx command to Gateway to make a connect R4 bind to a different Gateway (must make other gateway joinable with previous command or go on website and click joinable)
            -- send_command <device>, 'Bind, <R4 mac address>, <new gateway extPanId>, [optional]<AESkey>'
            -- ex) send_command 11383, 'Bind, 00:0d:6f:00:00:c6:11:d7, AZG70010' //no password
            -- ex) send_command 11383, 'Bind, 00:0d:6f:00:00:c6:11:d7, AZG70010, aa:c9:9a:cb:61:ca:70:e7:13:df:ee:6f:d6:42:59:86'

General Notes:

  • SW5791_01A_NXR_ZGW_v3_00_00.kit
  • SW5791_07_ZIGBEE_REPEATER_v3_01_05.kit
  • SW5795_92_ZIGBEE_END_DEVICE_v3_01_05.kit

The above 3 kit files are included in both the 3.01.13 and 3.01.17 zip files just in case you need them.​

It is important to leave the gateway alone while it is updating firmware, no accessing the web browser for at least 5 minutes after the kit file transfer from Netlinx Studio finishes.

CAUTION: 

If you're upgrading your zigbee gateway and the gateway currently has a version less than 3.00.00, AND you have repeaters in the system, after you upgrade the gateway, the repeaters will no longer work. The repeaters had to be sent in for repair to be upgraded to work with version 3 firmware, this service is no longer offered. If repeaters are integral to your installation, I would think twice before upgrading the gateway.

 

There are 3 lines below in RED, you will start with the instructions under the line that covers your scenario
A. Starting with a gateway version less than 3.00.00
B. Starting with a gateway version of 3.00.00 or version less than 3.01.07
C. Starting with a gateway version of 3.01.07 or higher.​

For example: 
If you are starting with gateway version 1.01.20, you would do both A then B.
If you are starting with 3.00.00, you would do only B.
If you are starting with 3.01.05, you would do only B.
If you are starting with 3.01.07 you would do only C.


Known Issues:

  •  NXR-ZGW firmware v3.00.00
  •  Zigbee Coordinator firmware v3.00.00
  •  NXR-ZRP firmware v3.00.00
  •  R4 ZigBee module firmware v3.00.00​
  • For the proper operation of all devices, it is recommended that all devices be brought up to the most current firmware version.

Loading procedures:

When upgrading from any version less than v3.00.00:

  1. Upgrade to v3.00.00 first (example:  v1.01.20 -> v3.00.00)
    The upgrade from v3.00.00 to v3.01.xx will require two loads of the file SW5791_01A_NXR_ZGW_v3_01_xx.kit.  The first load will fail after the third file is transferred with the NetLinx error message “Transfer Aborted - Unsupported file type.”  After getting this error message, reboot the gateway and verify that the NetLinx OnLine Tree shows v3.01.xx for the version on the gateway.  Transfer file SW5791_01A_NXR_ZGW_v3_01_xx.kit to the gateway a second time with the “Reboot Device” box checked in NetLinx. This time the entire kit file will transfer.  After the gateway reboots, it will download the firmware to the radio.  This will take approximately two minutes.
  2. Load SW5795_92_ZIGBEE_END_DEVICE_v3_01_05.kit -- a gateway reboot IS NOT necessary after sending this file.
  3. Load SW5791_07_ZIGBEE_REPEATER_v3_01_05.kit -- a gateway reboot IS NOT necessary after sending this file.

When upgrading from v3.00.00 or a version less than 3.01.07:

  1. The upgrade from v3.00.00 to v3.01.xx will require two loads of the file SW5791_01A_NXR_ZGW_v3_01_xx.kit.  The first load will fail after the third file is  transferred with the NetLinx error message “Transfer Aborted - Unsupported file type.”  After getting this error message, reboot the gateway and verify that the NetLinx OnLine Tree shows v3.01.xx for the version on the gateway.  Transfer file SW5791_01A_NXR_ZGW_v3_01_xx.kit to the gateway a second time with the “Reboot Device” box checked in NetLinx. This time the entire kit file will transfer.  After the gateway reboots, it will download the firmware to the radio.  This will take approximately two minutes.
  2. Load SW5795_92_ZIGBEE_END_DEVICE_v3_01_05.kit -- a gateway reboot IS NOT necessary after sending this file.
  3. Load SW5791_07_ZIGBEE_REPEATER_v3_01_05.kit -- a gateway reboot IS NOT necessary after sending this file.


When upgrading from v3.01.07 or higher:

  1. Transfer the file SW5791_01A_NXR_ZGW_v3_01_xx.kit to the gateway via NetLinx with the "Reboot Device" box checked in NetLinx. It is not necessary to reload SW5795_92_ZIGBEE_END_DEVICE_v3_01_05.kit or SW5791_07_ZIGBEE_REPEATER_v3_01_05.kit since these files have not changed in this release.
  2. Recommission all devices on the network.

Related Videos

update upgrade

Was this article helpful?

Yes
No
Give feedback about this article

Table of Contents

Brands: Models: Downloads: Information: General Notes: CAUTION: Known Issues: Loading procedures:

Related Articles

  • DVX Switcher device not appearing on the online tree
  • Precis login issues
  • Enable ping responses on Acendo Core
  • How To Load TPDesign3 on a Windows 10 Computer
  • N2410 Windowing Processor and N24xxA enc/dec Compatibility

Related Articles

  • DVX Switcher device not appearing on the online tree
  • Precis login issues
  • Enable ping responses on Acendo Core
  • How To Load TPDesign3 on a Windows 10 Computer
  • N2410 Windowing Processor and N24xxA enc/dec Compatibility
Copyright © HARMAN Professional. All rights reserved. Privacy Policy | Terms of Use
Expand