​​Product Version 1.3.7 Release Notes

  • Added Support for PTPV2​​


NOTE FOR ​​​​DDM USERS NOT USING RTP AUDIO/AES67

DDM​ Settings

The AES67 parameter for the Soundweb London device in Audio Architect must be disabled when the device is enrolled in a Domain.  This applies to all of the clocking modes in Dante Domain Manager [DDM] except AES67.  If you require AES67 Clocking Mode in a domain, instructions can be foundhere​​​.

​Soundweb Lon​don Set​tings

​Update the Firmware

​There is a specific build of firmware for using Soundweb London in DDM without AES67.  Download the firmware in this article [v1.3.7.0] from the link on the right. --->

  • ​​Import the Dante Firmware File for Product Version 1.3.7.0 into Dante Updater.

  • Update the Firmware on Devices used in the Domain.

Device S​​​​ettings

  • The AES67 parameter is found under the device properties in Audio Architect.

  • In Audio Architect, single click twice to highlight the Device in the rack.
  • Select the Dante Tab.
  • For AES67 Enabled select No.
  • Go Online and load the devices.

Using Soundweb London in Dante Domain Manager Without AES67 Picture1.png

This must be done for each Dante device in the Audio Architect file.

 ​​ 

Dante Domain ​Manager Settings

This parameter is found under the Domain Parameters within Dante Domain Manager.​​

mode.png

Note: This setting must match between Audio Architect and the setting in DDM for this Domain.  Having a mismatch will affect connectivity in Dante Controler and result in loss of audio.  ​