ZonePRO Designer Com Port Selection
Table of Contents
Brand:
- dbx
Models:
- ZonePRO 640
- ZonePRO 640m
- ZonePRO 1260
- ZonePRO 1260m
- ZonePRO 641
- ZonePRO 641m
- ZonePRO 1261
- ZonePRO 1261m
ZonePRO GUI Designer will not discover or connect to a ZonePRO device.
When trying to connect to a ZonePRO device via RS232 and it will not discover or connect. It is recommended to use COM port 1- 4
Even though you can select COM ports above 4 in ZonePRO GUI Designer, they sometimes will not work correctly. If this is your case, change the USB to serial adaptor's comm port in Device Manager to one of the ports 1 - 4.
- Open Device Manager by right clicking the Windows start icon and selecting Device Manager.

- Right click on your device and select Properties.

- Under Port Settings, click the Advanced button.

- Change the Comm port number to a number between 1 and 4. If you have those ports already taken, follow this procedure on another port to change it to free up a comm port between 1 and 4, then change this adaptor.

Note: If the Serial Adapter doesn't show up as a port under “Ports (COM and LPT)" or shows as “Other" with an exclamation point (!), contact adapters manufacturer as the device driver is not installed correctly and will not connect.