Question:
How do I factory reset my Lexicon LXP-1?
Answer:
Warning! This will erase all user register and patch information.
- Power off the unit.
- Turn the Program Knob to Plate D.
- Set the Decay and Delay knobs to the down position (6 o'clock).
- Press and hold in the MIDI button and apply power to the unit.
- Release the MIDI button and then press it again, just once. The MIDI LED will flash once.
- Turn the Program knob to HALL B and the Decay and Delay knobs one position CW (clockwise).
- Press and release the MIDI button once. The MIDI LED will flash once.
- Turn the program knob to Hall D.
- Press and release the MIDI button once more. This time the MIDI LED will flash OFF/ON at a fast rate.
- Power the unit OFF.
- Power the unit ON.
- Turn to any preset.
The memory clear operation is complete.