Heading 1:
| Name |
Short Code: [3 characters] |
Medium Code: [4 characters] |
Long Code: [16 characters] |
Descriptive message [ LCD display ] |
LED indicator |
RDM status ID code |
Description |
| Lamp life | LTI | LTIM | LAMP LIFETIME | Lamp lifetime | Orange blinking | 0x8000 | Lamp has less than 10% of it expected lifetime left. |
| Door open | DOOR | LAMP DOOR OPEN | Lamp door open | Orange blinking | 0x8001 | Lamp door is open and it is not possible to strike the lamp. | |
| Hot lamp | HOT | HOT | LAMP HOT | The Lamp is HOT Remaining time XX min | Orange blinking | 0x8002 | Shown when lamp has been struck but didn’t come on. Lamp is hot and it is not possible to turn it on (non hot restrike fixtures only!). |
| EEprom warning | EEPR | EEPROM INVALID |
EEprom invalid/No conn
|
Orange blinking | 0x8007 |
EEprom communication failed contact Martin Support.
|
|
| Bank warning | BANK | BANK NO ACCESS | Unable to unpack bank | Orange blinking | 0x8008 | Bank has been copied to fixture but not able to unpack it. | |
| Air filter warning | AIRS | CHECK AIRFILTERS | Air filter needs service | Orange blinking | 0x8009 | Air filter timer has timed out. | |
| Dimmer warning | DINA | DIMMER ADJUST | Dimmer not adjusted | Orange blinking | 0x800A |
No dimmer adjustment data in EEprom.
|
|
| Shutter warning | SHNA | SHUTTER ADJUST | Shutter not adjusted | Orange blinking | 0x800B |
No shutter adjustment data in EEprom.
|
|
| Pan warning | PANA | PAN ADJUST | Pan not adjusted | Orange blinking | 0x800C | No Pan adjustment data in EEprom. | |
| Tilt warning | TINA | TILT ADJUST | Tilt not adjusted | Orange blinking | 0x800D | No Tilt adjustment data in EEprom. | |
| USB warning | FUSB | USB UPLOAD | Forced USB upload enable | Orange blinking | 0x800E | The fixture was started in forced upload mode (esc held during power up). | |
| Battery warning | BATM | BATTERY MODE | Battery mode | Orange blinking | 0x800F | Changed to battery power source. | |
| Pan temperature warning | GxyM | GOBO x–y MISSING |
Gobo wheel x Gobo y missing |
Orange blinking |
0x8010 – 0x80FF |
Gobo y on gobowheel x was not seen during reset. If all gobos on a gobowheel is not seen, a RxER will also be set. |
|
| Mains warning | MALW | MAINS LOW | Mains low | Orange blinking | 0x8100 | Mains voltage is below acceptable level, lamp may not be able to strike. | |
| Upload mode | UPL | UPL | UPLOAD MODE | Upload mode | Orange blinking | 0x8101 | Shown in display if fixture is in upload mode. |
| Invalid License Key | INLK | INVALID LICENSE KEY | Invalid License Key | Orange blinking | 0x8102 | Shown for 5 seconds when invalid license key is entered | |
| Decrypting License Key | DELK | DECRYPTING LICENSE KEY | Decrypting License Key | Orange blinking | 0x8103 | Shown as long license key is decrypted. | |
| CMY PCB temperature warning | CMTW | CMY TEMP HIGH | CMY PCB temp too high | Orange blinking | 0x8104 | CMY PCB temperature sensor continuously measures a temperature above normal operating temperature | |
| Effect PCB temperature warning | EFTW | EFF TEMP HIGH | Effect PCB temp too high | Orange blinking | 0x8105 | Effect PCB temperature sensor continuously measures a temperature above normal operating temperature | |
| Zoom focus PCB temperature warning | ZFTW | ZF TEMP HIGH | Zoom focus PCB temp too high | Orange blinking | 0x8106 | Zoom focus PCB temperature sensor continuously measures a temperature above normal operating temperature | |
| Pan tilt PCB temperature warning | PTTW | PT TEMP HIGH | Pan tilt PCB temp too high | Orange blinking | 0x8107 | Pan tilt PCB temperature sensor continuously measures a temperature above normal operating temperature | |
| UI PCB temperature warning | UITW | UI TEMP HIGH | UI PCB temp too high | Orange blinking | 0x8108 | UI PCB temperature sensor continuously measures a temperature above normal operating temperature | |
| PSU PCB temperature warning | PUTW | PSU TEMP HIGH | PSU PCB temp too high | Orange blinking | 0x8109 | PSU PCB temperature sensor continuously measures a temperature above normal operating temperature | |
| BAL PCB temperature warning | BATW | BAL TEMP HIGH | Ballast PCB temp too high | Orange blinking | 0x810A | Ballast PCB temperature sensor continuously measures a temperature above normal operating temperature | |
| Frost not adjusted warning | FTNA | Frost not adjusted | Orange blinking | 0x810B | No frost adjustment data in EEprom. | ||
| New firmware required warning | FW | NEW FW REQUIRED | New Firmware required | Orange blinking | 0x810C | Fixture requests upload of new firmware | |
| Barndoor not adjusted warning | BDNA | BARNDOOR NOT ADJUSTED | Orange blinking | 0x810D | No barndoor adjustment data in EEprom. | ||
| Service mode warning | SERV | SERVICE MODE | Service mode enabled | Orange blinking | 0x810E | Fixture is in service mode. | |
| Safety loop warning | SL W | SAFETY LOOP | Safety loop error occurred | Orange blinking | 0x810F | A safety loop error occurred, but is no longer active. Warning is cleared on power off. | |
| Framing not adjusted warning | FRNA | FRAMING NOT ADJUSTED | Orange blinking | 0x8110 | No framing adjustment data in EEprom. | ||
| Wash Effect not adjusted warning | WENA | Wash Effect not adjusted | Orange blinking | 0x8111 | No Wash adjustment data in EEprom | ||
| Quadray not adjusted warning | QRNA | QUADRAY NOT ADJUSTED | Orange blinking | 0x8112 | No Quadray adjustment data in EEprom. | ||
| LED driver temperature warning | LDTW | LED DRV TMP HIGH | Orange blinking | 0x8113 | The LED driver PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| BEAM pixel board temperature warning | BETW | BEAM TMP HIGH | Orange blinking | 0x8114 | The Beam LED PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| AURA pixel board temperature warning | AUTW | AURA TMP HIGH | Orange blinking | 0x8115 | The Aura LED PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| PFC temperature warning | PFTW | PFC TMP HIGH | Orange blinking | 0x8116 | The PFC PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| DC/DC temperature warning | DCTW | DC TMP HIGH | Orange blinking | 0x8117 | The DC-DC PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| Quadray temperature warning | QRTW | QR TMP HIGH | Orange blinking | 0x8118 | The Quadray PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| Beam twist not adjusted | BTNA | BEAMTWIST ADJUST | Orange blinking | 0x811A | Beam twister lens not adjusted | ||
| Fan warning | FAN | LAMP R FAN | Orange blinking | 0x811B | Fan has been steadily underperforming by X RPM for Y seconds | ||
| Fan warning | FAN | LAMP L FAN | Orange blinking | 0x811C | Fan has been steadily underperforming by X RPM for Y seconds | ||
| Framing board temperature warning | FRTW | FRAMING TMP HIGH | Orange blinking | 0x811D | Framing PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| IBD board temperature waring | IBTW | IBD TMP HIGH | Orange blinking | 0x811E | IBD PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| Current Driver temperature warning | CCTW | CC DRIVER TEMP HIGH | Orange blinking | 0x811F | The Constant currant driver PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| Pan temperature warning | PNTW | PAN TEMP HIGH | Orange blinking | 0x8120 | Pan driver PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| Tilt temperature warning | TLTW | TILT TEMP HIGH | Orange blinking | 0x8121 | Tilt driver PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| Framing 2 not adjusted warning | F2NA | FRAMING2 ADJUST | Orange blinking | 0x8122 | Framing not adjusted | ||
| Framing 2 board temperature warning | F2TW | FRAMING2 TMP HIGH | Orange blinking | 0x8123 | Framing 2 driver PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| LED board temperature warning | LETW | LED BOARD TEMP HIGH | Orange blinking | 0x8124 | LED PCB temperature sensor continuously measures a temperature above normal operating temperature | ||
| LED board EEPROM | LEEP | LED BOARD EEPROM | Orange blinking | 0x8125 | LED Board EEPROM device not mounted or connection has failed | ||
| Wet too long | WTTL | WET TOO LONG | Orange blinking | 0x8126 | Fixture has been wet for an extended period. To remove the warning, a complete dry-off procedure is required | ||
| Drying out | DRYO | DRYING OUT | Orange blinking | 0x8127 | Drying off function activated | ||
| Empty water needed | NEMW | NEED EMPTY WATER | Orange blinking | 0x8128 | Water buildup in front of head. Draining required | ||
| Emptying water | EMPW | EMPTYING WATER | Orange blinking | 0x8129 | Fixture draining water from front of head | ||
| Connectors facing upwards | CTUP | CONNECTORS UPWARD | Orange blinking | 0x812A |
Fixture base is installed with connectors facing upward, where there is a risk of water accumulation in case of rain |
||
| Serial Number Mismatch | SRNM | SR NO MISMATCH | Orange blinking | 0x812B | CMY module, Light Engine or Main board may have different serial numbers. | ||
| Dry out function recommended | DRYR | DRY OUT FUNC RECOM | Orange blinking | 0x812E | Product has detected it has been wet and needs drying out. | ||
| NFC Warning | NFCW | NFC WARNING | Orange blinking | 0x812F | NFC communication works, but we are unable to initialize the data in the tag | ||
| Safe Parking warning | PARK | SAFE PARKING | Orange blinking | 0x8130 | Safe parking to avoid sun damage / rain buildup in head. | ||
| Animation wheel rotate warning | AWRM | AW ROT MISSING | Orange blinking | 0x8131 | Animation wheel rotation not indexing | ||
|
Air temperature high |
AITW | AIR TEMP HIGH | Orange blinking | 0x8132 | Air temp high | ||
| Air humidity high | AIHW | AIR HUMIDITY HIGH | Orange blinking | 0x8133 | Air humidity high | ||
| No Dimming Zones defined | DMZQ | NO DIMMING ZONES | Orange blinking | 0x8134 | No Allowed Dimming Zones enabled |