Managing Sleep Mode on the PSB-1
Table of Contents
Brand:
- JBL
Models:
- PSB-1
Overview:
The PSB-1 automatically enters standby mode after an extended period without detecting a valid audio signal. When a qualifying signal is present, the amplifier will remain active or wake from standby as needed.
Sleep Mode Behavior:
The PSB-1 uses the same signal detection criteria for both waking from standby and preventing standby.
If the amplifier detects a valid signal, it will either:
- Wake from standby if currently asleep, or
- Reset the standby timer if already active
A valid signal is defined as:
- Audio content between 20 Hz and 20 kHz
- A signal level of -21 dBu or greater
There are no separate sensitivity thresholds for these functions.
Signal Duration Requirements:
The signal only needs to be present briefly to be recognized as activity. In most applications, a signal lasting 2 to 5 seconds is sufficient to reliably reset the standby timer.
Using a Pilot Tone:
Installed systems may use a high-frequency pilot tone to keep the PSB-1 active during periods of inactivity.
For best results:
- Use a tone between 19 kHz and 20 kHz
- Ensure the signal arriving at the PSB-1 is at least -21 dBu
- Transmit the tone periodically before the standby timeout period expires
- Use a tone duration of approximately 2 to 5 seconds
When these conditions are met, the amplifier should remain awake rather than entering standby.
Frequently Asked Questions:
Does the same signal wake the unit and keep it awake?
Yes. The PSB-1 uses the same detection criteria for waking from standby and for resetting the standby timer.
Are different signal levels required for wake-up and sleep prevention?
No. A qualifying signal above the detection threshold performs both functions.
How long does the signal need to be present?
A few seconds is typically sufficient. A duration of 2 to 5 seconds is recommended for consistent operation.
Can Standby Mode be disabled?
No, standby mode cannot be disabled.
Troubleshooting Unexpected Standby Events:
If the PSB-1 enters standby when it should remain active:
- Verify the signal level at the amplifier input is at least -21 dBu.
- Confirm any pilot tone or audio signal falls within the detectable frequency range.
- Check DSP, routing, and gain settings that may reduce the signal level before it reaches the PSB-1.
- Increase the pilot-tone duration to 2 to 5 seconds if shorter bursts are being used.
Table of Contents