Anytime Help Center

SDX Solecis 2K Series Digital Switcher Firmware

Rating


Included Products:  
  FG1010-315 (SDX-510M-DX, 5-input Transmitter Module)
  FG1010-304 (SDX-410-DX,  4-Input Transmitter Module)
  FG1010-308 (SDX-810-DX,  8-Input Transmitter Module)
 
Solecis Digital Switcher Firmware: v1.4.16
Release Date: 3/14/2017

Previous Solecis Digital Switcher Firmware: v1.4.15
Release Date: 9/27/2016

README.TXT File Contents

1. Prerequisites
2. Features added in this release
3. Fixes in this release:
4. Known Issues
5. Programming Information
6. Notable Points


----------------------------------------------------------
1. Prerequisites
----------------------------------------------------------

- For directly connected DXLink Receivers, the DXLink Receiver must use DXLINK-HDMI-RX firmware version
  v1.9.21 (or later).

- For connecting to Enova DGX enclosures over DXLink, the Enova DGX will need the following FW versions:
    - For Enova DGXs with NX Masters: Enova DGX NX Master FW v1.2.312 (or later)
    - For Enova DGXs with NI Masters: Enova DGX 8/16/32 NI Master FW v4.2.395 (or later)
    - Enova DGX 8/16/32/64 FW  v2.0.0.12  (or later)

- Enova DVX 3x55 and 2x55 version enclosures will need DVX-3x5x/2x5x Switcher Firmware v1.6.31  (or later)
   

- To allow communication/control from the DVX2x55 or DVX3x55 to the DXLink TX device, Ethernet on
  the DXLink Input(s) may need to be enabled. A DXLINK_IN_ETH-AUTO command may need to be sent to the DVX.  
  Reference the DVX Operation Reference Guide for details.

- NetLinx Studio NetLinx Studio V3.4 (4.0 if using NX master)

----------------------------------------------------------
2. Features added in this release:
----------------------------------------------------------
== Previously released in v1.4.10 ==========================
- Added an "Offline Recovery Mechanism." In a telnet session,
  type "WD ON" to enable or "WD OFF" to disable this feature.
  A reboot is required after enabling or disabling the state
  for it to take effect. This also monitors the following
  conditions, and when met it will reboot:
  - If it successfully connects to a Master and then falls
    offline for longer than 5 minutes.
  - A DXLink device processor becomes unstable and hangs
  - The DXLink device’s exceeds it's minimum memory threshold

- Added a watchdog for point to point setups.  In a telnet session,
  type "wdp2p on x.x.x.x" to enable.  The x.x.x.x is the ip address
  of the opposite device.  To disable, in a telnet session type "wdp2p off".
  A reboot is required after enabling or disabling the state
  for it to take effect.  Leave the RX and MFTX in static ip mode.  
  Once the devices ping each other the watchdog will be armed.
  If they fail to ping each other for 1 minute the watchdog will fire.

-  Connection watchdog when connected to a master.  Will improve online/offline.
   Do not use if not configured to connect to a Master.
   wdurlsocket on  - enable the watchdog
   wdurlsocket off - disable the watchdog (default setting)

== Previously released in v1.4.4 ==========================
- DIP4 for setting DIRECT mode

----------------------------------------------------------
3. Fixes in this release:
---------------------------------------------------------
Fixed an issue where VIDIN_HDCP-disable wasn't persistent through reboot.

== Previously released in v1.4.16 ==========================

Disable ftp access via no password

== Previously released in v1.4.15 ==========================

Removed delay in detecting video.

== Previously released in v1.4.14 ==========================

Fixed an issue where VIDIN_FORMAT reported DVI for HDMI sources.

== Previously released in v1.4.13 ==========================

Fixed an audio issue when switching to analog sources on 5x1s.

== Previously released in v1.4.11 ==========================

Improved reporting of video details to the DGX webpage.

== Previously released in v1.4.11 ==========================

-Fixed a memory leak.

-Fixed an issue where the video color space value
would not report correctly on DGX webpage.

== Previously released in v1.4.9 ==========================
-Fixed audio and video details synchronization issues.

-Force to auto-setup button now works correctly.

== Previously released in v1.4.4 ==========================
- case insensitive arguments for EXTERNAL_BUTTON_ACTION


----------------------------------------------------------
4. Known Issues
----------------------------------------------------------
None

----------------------------------------------------------
5. Programming Information
----------------------------------------------------------
None
    
----------------------------------------------------------
6. Notable Points
----------------------------------------------------------
- PLEASE READ the documentation in regard to the DIP switches located on the Solecis Digital Switcher
before attempting to connect to the network

Downloads

Product

 

Topic

Firmware

Related Articles

Last modified at 7/2/2020 1:13 PM by PRO Knowledge Base
Top