DMX state (behavior when DMX signal stops)
You can define the behavior of the fixture if it is powered on and the DMX signal stops. The fixture is set to Blackout by default.
To set fixture behavior if the DMX signal stops:
1. Select DMX STATE and press ENTER to confirm.
2. Use the UP and DOWN buttons to select:
• MASTER/CLIENT – fixture runs in Master/Client mode as described above. The first fixture on the link (master) automatically sends synchronizing information to other connected fixtures (clients).
• BLACKOUT – fixture blacks out.
• HOLD – fixture continues to obey the last command that was sent via DMX.
3. Press ENTER to confirm (or press MENU to exit without making a change).