Product Name: NX-1200, NX-2200, NX-3200, NX-4200 Master Controllers
Enova DVX-x2xx
Enova DGX 8/16/32/64
Massio Control Pads MCP-10x
Enova DGX 800/1600/3200/6400
FG #: FG2106-01, FG2106-02, FG2106-03, FG2106-04,
FG1901-16,
FG1906-07, FG1906-09, FG1906-11,
FG1906-12, FG1906-13, FG1906-14, FG1906-15,
FG1906-16, FG1906-17, FG1906-18, FG1906-22,
FG1060-08, FG1060-16, FG1060-32, FG1060-64,
FG2102-06L-B, FG2102-06L-W, FG2102-06P-B,
FG2102-06P-W, FG2102-08-B, FG2102-08-W
FG1061-08, FG1061-16, FG1061-32, FG1061-64
Device ID: 0x018C, 0x1B5, 0x1B1, 0x01B2, 0x1B8, 0x1E9
----------------------------------------------------------
Prerequisites
----------------------------------------------------------
When upgrading from 1.3.106 or earlier, you must first upgrade to 1.4.90.
----------------------------------------------------------
Programming Information
----------------------------------------------------------
Use of these new Authentication keywords requires Netlinx.axi v1.62.
The NetLinx language supports the following new Authentication keywords:
TLS_CLIENT_CLOSE
TLS_CLIENT_OPEN
For details on the new keywords, please see the NetLinx Language Reference Guide.
IMPORTANT: If needing to downgrade from any 1.8.xxx version to any 1.6.20x version, you must disable Authentication on Server Ports on the General tab of the Webgui prior to downgrading. After downgrade, you will need to do a reset factory to properly reset the password paths. This will also re-enable the security. Then reload your code.
----------------------------------------------------------
Changes in this release
----------------------------------------------------------
v1.8.197
- Fixed a bug with certificate loading on v1.8.195
v1.8.196
- Fixed bug causing no OFFLINE event when calling IP_CLIENT_CLOSE
v1.8.195
- upgrade openssh to "SSH-2.0-OpenSSH_9.8"
v1.8.193
- Fixed bug with URL entry when using port 1320
v1.8.192
- Fixed SSH_CLIENT_OPEN/CLOSE bug
v1.8.187
- Added icsp/Telnet upper case support for send_string, send string, send_level, send level, and send_command, send command
Eg. SEND_STRING, SEND STRING, SEND_LEVEL, SEND LEVEL, SEND_COMMAND, SEND COMMAND
v1.8.186
- Fixed icsp tls issue connections with controller to controller and controller to panel HPSD-29164 and HPSD-29209
v1.8.184
- upgrade TLSv1_2 to TLSv1_3
v1.8.183 (Release)
- Added support for new DXLink 4K60 DWP TX in Webgui of DGX and DVX4k
- Improved boot time to be faster (except for High Security Mode which takes a few minutes longer due
to security key creation and authentication)
- Fixed issue with telnet URL list commands causing telnet session to lock up when deleting URL item
- Fixed static ip gateway persistence issue during upgrade from 1.6.x to 1.8.x firmware
- Fixed telnet Master to Master issue
See v1.8.183 Readme for earlier version history
----------------------------------------------------------
Known Issues
----------------------------------------------------------
----------------------------------------------------------
Known Issues
----------------------------------------------------------
- If upgrading from 1.6 firmware, wpa_supplicant updates will need to be re-done
- The following RMS SDKs are not compatible with 1.5.68 and higher:
RMS SDK 4.0-4.3.26, RMS SDK 4.4.* and RMS SDK 4.5.*
- When changing between the local and remote directories for user authentication,
the master requires a reboot to force all currently logged in users to
re-authenticate with the new service.
- SSH Key algorithm supports only ssh-rsa host key.
- ICSPMon will not work with port authentication on or telnet disabled.
- The USB host ports do not support USB hubs.
- Performing a PING to the NX master's IPv6 address may cause the NX master to reboot.
- Master web page login may get stuck in MS-IE browser on Windows8. Either use a
different browser or in Internet Options->Advanced->Security Settings check
"Enable Enhanced Protection Mode*" (Windows8 restart required).
- Dynamic images and listview features require v.1.4.9 G5 touch panel firmware if NX security is enabled.
- Dynamic images will not work with G4 touch panels with NX security enabled.
- IP_MC_SERVER_OPEN command does not work on the ICSLan port.
- The DVX-x2xx Switcher (5002) requires firmware v1.7.54 or higher if authentication is enabled for AMX devices
on ICSLAN or LAN Ports.
- The DGX Switcher (5002) requires firmware v3.2.10 or higher if authentication is enabled for AMX devices
on ICSLAN or LAN Ports.