​​I-Tech HD LevelMAX™ Limiter Suite 

 

The I-Tech HD LevelMAX™ Limiter Suite features three types of limiting:

  • Peak 
  • RMS 
  • Transducer Thermal  

And two modes of operation:

  • Auto
  • Advanced  

The standard I-Tech HD LevelMAX Limiter panel (Advanced Mode) is shown below:

Capture 1.png 

 

LevelMAX  has  been  designed  to  limit  accurately  to  the  specified  voltage  thresholds.  The addition of a thermal limiter allows thresholds for the faster-acting RMS and peak limiters to be set higher, providing  more output  and  maintaining  dynamic range  before  the onset of  limiting, while protecting the long term integrity of the transducers.  

In  Auto  or  Advanced  modes,  turning  on  the  LevelMAX  Limiter  Suite  will  enable  all  three limiters: Peak, RMS and Thermal.

The three LevelMAX limiter types and operating modes are outlined in the following sections. 

 

1.0 LevelMAX Peak Limiter 

LevelMAX  Peak  limiting  instantaneously  limits  the  output  voltage  to  not  exceed  the  defined peak threshold voltage.

 

1.1   Peak Limiter Threshold (Vpk) 

 

Vpk = SqRt(2)*VRMS

In  Auto  mode,  the  peak  limiter  threshold  value  is  automatically  determined  from  the  defined RMS  threshold  and  the  low  pass  frequency  defined  in  the  XOVER  block.  For  a  low  pass frequency less than 100  Hz, the RMS  to peak threshold ratio is 6  dB. From 100  Hz to 400  Hz, the RMS to peak ratio increases from 6 dB to 9 dB. Above 400 Hz, the ratio remains at 9 dB.

For Advanced mode, the peak limiter threshold can be set by the user.   

 

1.2 Peak Limiter Attack (sec) 

 

The  peak  limiter  attack  time  is  instantaneous  and  cannot  be  modified.  The  output  voltage  is limited to the value defined by the peak limiter threshold (see 1.1).

 

1.3 Peak Limiter Release (sec) 

 

In Auto mode, the peak limiter release time is determined by the high pass frequency defined in the XOVER block.

For Advanced mode, the peak limiter release time can be set by the user.

 

1.4 Peak Limiter Look-Ahead

 

Peak Limiter Look-Ahead inserts a delay into the peak limiter signal path in order to 'look' at the input  signal  and  anticipate  when  the  peak  threshold  will  be  exceeded.  If it detects that the threshold will be exceeded, the signal is gradually reduced prior to reaching the threshold, while still limiting to the correct peak voltage. This approach eliminates a sharp signal discontinuity which, in turn, could create audible distortion. 

The peak limiter look-ahead value is 0.5ms.  This value was determined to be subjectively acceptable for most frequency ranges while not adversely compromising overall latency. Overall latency remains constant regardless of whether the LevelMAX Limiter suite is enabled (ON) or bypassed (OFF). 

 

 

2.0 LevelMAX RMS Limiter

 

LevelMAX RMS limiting accurately limits the output signal to the specified RMS threshold voltage.

 

2.1 RMS Threshold (VRMS)

 

The RMS Threshold should be set by the user to correspond to the short term (2 hour) power handling of the transducer or system.

Refer to the appropriate JBL Specification Sheet, Technical Manual or Product Manual for two hour power ratings. To calculate the RMS Threshold in VRMS, use the following equation: 

RMSThreshold (Vrms) = SqRt (AES Power (Wrms, 2 hour) x Minimum Impedance (ohms)) where AES Power (Wrms, 2 hour) is the free air component power rating.

If minimum impedance data is unavailable, use nominal impedance. If 2 hour AES power ratings are unavailable, use 2 hour IEC power ratings.  For most applications, it is recommended to operate LevelMAX limiters in Auto mode so that peak thresholds are automatically calculated based on the RMS threshold and selected LP frequency (see 1.1).

2.2 RMS Attack Time

 

The RMS attack time is set automatically in Auto or Advanced modes  and is based on the peak limiter release time. The RMS attack time has been designed to smoothly transition from peak to RMS limiting while minimizing audible limiter anomalies.

2.3 RMS Release Time

 

For Auto mode, the RMS release time is determined based on the high pass frequency that is defined in the XOVER block.

For Advanced mode, the RMS release time can be set by the user.  

2.4 RMS Detector Time

 

The RMS Detector Time is determined based on the high and low pass frequencies defined in the XOVER block and is not user-adjustable.

 

3.0 LevelMAX Transducer Thermal Limiter

 

LevelMAX Transducer Thermal limiting is designed to protect transducers from long term thermal damage by gradually adjusting the RMS threshold until the target long term thermal threshold voltage has been reached. The thermal limiter functions only when the RMS limiter is enabled and when the thermal voltage threshold is lower than the RMS threshold. On the main limiter panel, the thermal protection LED turns on once the thermal limiter is 0.75 dB into limit.

 

3.1. Thermal Voltage (VRMS)

 

The thermal voltage threshold should be set to correspond to the long term (100 hour) power handling of the transducer or system. Refer to the appropriate JBL Specification Sheet, Technical Manual or Product Manual for 100-hour power ratings. To calculate the Thermal Voltage Threshold in VRMS, use the following equation:

Thermal Threshold (Vrms) = SqRt(Power (Wrms, 100 hour) x Nominal Impedance (ohms)) where Power (Wrms, 100 hour) is the 100 hour power rating.

If 100 hour power handling data is unavailable, set 100 hour power rating ≈ 0.8 x 2 hour power rating.

 

3.2 Thermal Response Time(s)

 

The thermal response time is the amount of time the average RMS signal is above the thermal threshold voltage before limiting begins. Once the threshold has been exceeded for the amount of time defined by the thermal response time, the RMS threshold is lowered until the target thermal voltage has been reached. The thermal response time is not the time it takes to reach the target voltage, although the longer the thermal response time, the longer it takes to reach the target voltage. It is also dependent on the amount of gain reduction and the ratio between RMS and thermal thresholds.

Thermal response time is transducer-dependent and should be based on the initial temperature rise of the transducer voice coil to protect it from thermal overload. If detailed transducer data is unavailable, the Thermal Response Time should be left at the default value of 10 sec.

 

4.0 LevelMAX Parameters for I-Tech HD VerTec V4 device files


For I-Tech HD VerTec V4 device files, LevelMAX parameters are based on the automatic calculation of the values outlined in the previous sections and are set to Manual (JBL OEM Factory Locked) mode to reduce the potential for accidental modification of key parameters.  Thermal limiter response times were determined by measuring the initial temperature rise for each transducer. Taking 63% of the time taken to the projected temperature rise to 200ºC was used to determine the 'time constant' of the voice coil. The value entered into the thermal time constant was ½ of that value for smoothest transition from RMS to thermal limiting. HF units
were set to a slightly longer thermal time constant, due to their initial low operating temperature, while their long term voltage needs to be limited to the 100 hour threshold.  LevelMAX parameters for I-Tech HD VerTec V4 are summarized as follows:

Capture 2.png 

Appendix A:

Table of parameters modified by each mode with LevelMAX Limiter Suite enabled

Capture 3.png 

   Capture 4.png 

   Capture 5.png 


 

Appendix B:

LevelMAX Limiter panel in Auto and Advanced, offline and online.

 

Offline:

 Capture 6.png

 Capture 7.png

 

Online:

 Capture 8.png

Capture 9.png 