Anytime Help Center

G4 S SERIES TOUCHPANEL HOTFIX FIRMWARE

Rating

​​

Release Notes
-------------------------------------------------------------------------------
Product Name: Modero S Series Touch Panels

 
FG#: FG2265-01 MSD-1001-L, 10.1 MODERO S LANDSCAPE WALL TOUCH PANEL
     FG2265-02 MSD-701-L, 7.0 MODERO S LANDSCAPE WALL TOUCH PANEL
     FG2265-03 MSD-431-L, 4.3 MODERO S LANDSCAPE WALL TOUCH PANEL
     FG2265-05 MST-1001, 10.1 MODERO S LANDSCAPE TABLETOP TOUCH PANEL
     FG2265-06 MST-701, 7.0 MODERO S LANDSCAPE TABLETOP TOUCH PANEL
     FG2265-07 MST-431, 4.3 MODERO S LANDSCAPE TABLETOP TOUCH PANEL
     FG2265-31  MSD-1001-L2, 10.1 MODERO S LANDSCAPE WALL TOUCH PANEL
     FG2265-32  MSD-701-L2, 7.0 MODERO S LANDSCAPE WALL TOUCH PANEL
     FG571-07   HPX-MSP-7-BL, HYDRAPORT TOUCH CONN PORT 7 PANEL BLACK
     FG571-08   HPX-MSP-7-SL, HYDRAPORT TOUCH CONN PORT 7 PANEL SILVER
     FG571-09   HPX-MSP-10-SL, HYDRAPORT TOUCH CONN PORT 10.1 PANEL SILVER
     FG571-10   HPX-MSP-10-BL, HYDRAPORT TOUCH CONN PORT 10.1 PANEL BLACK
     

 
Current Firmware Version: 2.108.49
Release Date: 05/17/18

 
Device IDs: 0x0192 (MST-1001), 0x0193 (MSD-1001-L and MSD-1001-L2), 
            0x0190 (MST-701), 0x0191 (MSD-701-L and MSD-701-L2), 
            0x018E (MST-431), 0x018F (MSD-431-L),
            0x01D4 (HPX-MSP-7), 0x01D5 (HPX-MSP-10)

 
Prerequisites: 
TPDesign4 v3.3 build 674 or later, with G4 Support Files version 3.3.58 or 
later
Intercom module v1.9 or later (if using with Intercom)
SIP module 2.11 or later (if using with SIP)

 

 
-------------------------------------------------------------------------------
Changes in This Release
-------------------------------------------------------------------------------
***************************************************************
***********************2.108.49*******************************
***************************************************************
-- fixed several bugs with subpage scrolling that could freeze the
              subpage viewer button.

 
***************************************************************
***********************2.108.45*******************************
***************************************************************​
-- support for ^STS command to disable/enable subpage touch scrolling
-- support for ^SRO command to reset subpage ordering within a viewer
-- fixed Grandstream UCM-6102 SIP registration error
-- fixed sluggishness issue when MXA-MPL is enabled

 
***************************************************************
***********************2.108.40*******************************
***************************************************************​
-- Fix for hostname persistence when using static IP configurations on an
   MST-431 and MSD-431.
-- Added User-Agent field in HTTP headers for dynamic image downloads to
   support servers that require it.
-- Migrated to Dropbear SSH 2016.74 to address the following related 
   vulnerabilities; CVE-2016-7406 CVE-2016-7407 CVE-2016-7408 CVE-2016-7409.
-- Added fix for the Ping Command security issue.
-- Decreased the time for the Subpage scrolling to stop at its anchor
-- Fixed issue where the panel would either lockup or reboot due a memory leak
   and poor graphics memory management.
-- Fixed issue where the panel would reboot when the Computer Control window is 
   set to scaled to fit.

 
***************************************************************
***********************2.108.20*******************************
***************************************************************​​
-- Fix for hostname persistence when using static IP configurations on an
   MST-431 and MSD-431.
-- Added User-Agent field in HTTP headers for dynamic image downloads to
   support servers that require it.
   
-------------------------------------------------------------------------------
Addressed Common Vulnerabilities and Exposures List
-------------------------------------------------------------------------------
- CVE-2012-0920, CVE-2013-4421, CVE-2013-4434, CVE-2015-7547 CVE-2016-7406, 
- CVE-2016-7407, CVE-2016-7408, CVE-2016-7409

 
-------------------------------------------------------------------------------
Known Issues
-------------------------------------------------------------------------------

 
ETHERNET:
-- It is possible on some panels for the device's MAC address to get lost or 
   corrupted.  If this happens, the device will automatically generate a
   random MAC address.  This address is not guaranteed to a Globally
   Unique Identifier(GUI), but it will not conflict with any non-AMX devices.
   If the device is having connectivity issues, it is recommended that the
   "check eeprom" command be run from a telnet session.  This command will
   check the MAC address, and give the user the option to fix it.

 
VIDEO:
-- The following streaming video modes are supported for the 7" Modero S Touch 
   Panels: MPEG2 video and MP2/MP3 audio over MPEG2 Transport Streams 
   (from MAX-CSE or Vision2 Server), H.264 video and AAC audio over MPEG2 
   Transport Streams (from MXA-MPL or Vision2 Server), and Motion JPEG over 
   HTTP. 3rd Party MPEG2 and H.264 encoders have not been tested, are not 
   supported by AMX, and may or may not work.  Please see the Modero S 
   Programming Guide for more detailed recommendations on video configuration.
-- The following streaming video modes are supported for the 4.3" Modero S 
   Touch Panels: Motion JPEG over HTTP
-- Streaming Video/audio performance can depend on multiple factors, like: 
   downscaling ratio, network bandwidth, network congestion, other simultaneous
   panel activities, stream characteristics (bit rate, encoding method), etc. 
   There is no buffering on the panel for video streams (though there is a 
   small latency), so any anomaly in the network can result in a visible (or 
   audible) glitch. To help improve performance in challenging environments, 
   consider reducing the resolution of the content (480p is recommended), 
   reducing the bit rate of the stream, reducing the downscaling ratio, and 
   preserving the aspect ratio.
-- For any type of streaming video, there could be a 1-3 second latency. For 
   Motion JPEG, this latency can be improved by using smaller (i.e. < 800x480) 
   video buttons and/or reducing the frame rate of the server.

 
BLUETOOTH:
-- A Bluetooth handset (i.e. MXA-HST) can occasionally fail to reconnect 
   automatically if powered off or carried out of range, then brought back 
   into range. In this case, the user can manually reconnect by going to the 
   Bluetooth setup pages

 
RECOVERY:
-- It may take several presses to get the touch to register if attempting to 
   use the "Dots During Boot" firmware rollback method.  Firmware rollback is 
   also available from the Setup Pages menu if needed.

 

 
-------------------------------------------------------------------------------
Programming Information
-------------------------------------------------------------------------------

 
--Subpage Viewer--
^SRO-<vt addr range>
  Subpage reset order.  This command can be used to reset the order of subpages
  within a subpage viewer to the original order as specified by the panel design 
  files.
  
  Example: 
    Send_command 10001:1:0,'^SRO-1'

 
^STS-<vt addr range>,<enable state>
  Enabling subpage touch scrolling.  This command can be used to enable or 
  disable subpage touch scrolling for a given viewer button or set of viewer
  buttons.
  vt addr range – Specifies the address(es) of the subpage viewer button to be 
                  modified. 
  enable state - This value can be either "on" or "ON" or "1" to enable dynamic 
  reordering for the specified viewer button(s). Any other value will disable dynamic 
  reordering for the specified viewer button(s).  Subpage dynamic reordering is disabled 
  when the STS enable state is enabled.  When the STS enable state is disabled, subpage
  dynamic reordering is restored to the previous state as set by the last ^SDR command
  issued.

 
  Example: 
    Send_command 10001:1:0,'^STS-1,0'


 

Downloads

Product

 

Topic

Firmware

Related Articles

Last modified at 7/2/2020 3:12 PM by PRO Knowledge Base
Top