In firmware version 6.7.2.0, for the EON 710, 712 & 715, the CH1 and CH2 Sig/Clip LED status indicates the following:
- Muted channel – Red flashing
- No signal – Green solid (-inf dBu to -40dBu)
- Low signal – Green flashing (-40dBu to -12dBu)
- Loud signal – Yellow solid (-12dBu to 18dBu)
- Clipping signal – Red solid (18dBu and above)
Input level values above are with input gain set to 0dB.