Anytime Help Center

DVX-31xxHD and DVX 21xxHD Master Firmware

Rating

​​​​​​​

Please note that a readme file exists in the firmware zip file.

Release Notes

 

DVX-31xxHD-SP (-T) and DVX-21xxHD-SP (-T)

Enova Presentation Switcher with power Amp

 

FG#: FG1905-22 (DVX3156HD-SP)

FG#: FG1905-16 (DVX3155HD-SP)

FG#: FG1905-15 (DVX3150HD-SP)

FG#: FG1905-11 (DVX2150HD-SP)

FG#: FG1905-12 (DVX2155HD-SP)

FG#: FG1905-07 (DVX2110HD-SP)

FG#: FG1905-24 (DVX3156HD-T)

FG#: FG1905-18 (DVX3155HD-T)

FG#: FG1905-17 (DVX3150HD-T)

FG#: FG1905-13 (DVX2150HD-T)

FG#: FG1905-14 (DVX2155HD-T)

FG#: FG1905-09 (DVX2110HD-T)

 

Current Firmware Version:

Master: v4.8.336


RMS Transporter Update Manager Support:

---------------------------------------

This version includes support for the RMS Transporter Update Manager.  The NI must be

running device firmware (device 5001) version v1.31.6 or higher.  However, there is no

RMS Transporter Update Manager Support to upgrade the device firmware.  This will have

to be done using Netlinx Studio.

 

 

----------------------------------------------------------

Table of Contents

----------------------------------------------------------

 

1. Prerequisites

2. Features added in this release

3. Fixes in this release:

4. Notable Points

5. Programming Information

 

----------------------------------------------------------

1. Prerequisites

---------------------------------------------------------- 

   NI Device  5001: 1.31.6

   Switcher   5002: 1.6.31​

----------------------------------------------------------

2. Features added in this release:

----------------------------------------------------------

None 

----------------------------------------------------------

3. Fixes in this release:

----------------------------------------------------------

- Fixed LDAP processing to increase the maximum number of returned results allowed

- Fixed LDAP to limit the search scope to either the admin or user group

- Fixed LDAP return result checking to be case insensitive (which matches LDAP and NX master behavior)

- Fixed DATA.SOURCEIP so that it supports IPv6 addresses (for connection with NX master)

- Removed debugging account to prevent security vulnerability

- Fixed SSL certificate request form which wasn't storing user inputs

- Fixed SSL certificate values to be persistent through system reboot

- Upgraded OpenSSL to prevent security vulnerabilities

- Added new command 'set ssh version' which allows the user to disable support of

  SSH v1 and only allow SSH v2 connections

- Fixed issue when loading driver dependencies

- Altered LDAP to search for a user's groups using the bindDn information

- Removed LDAP processing when making an ICSP connection to match the NX's behavior and allow local users

  to continue to be valid.

- Fixed M2M CommandSize and StringSize message processing to allow for Port 0 (indicating all ports) to be

  specified.

- Increased LDAP URI, Base DN, Bind DN, User Query Attr parameters' max length from 100 to 255 and the search

  password max length from 100 to 128 to match the NX's behavior.

----------------------------------------------------------

4. Notable Points

----------------------------------------------------------

NOTE 1) : Once upgrading to this version you will not be able to downgrade the

          DVX to below v4.8.324.  This prevents scenarios where the DVX

          could hang at boot when using an earlier version of firmware which

          does not allow for the wider variety of CompactFlash card

          manufacturers now supported. 

NOTE 2) : To ensure a successful firmware upgrade with this release please

          refer to the file "SW1905-15-DVX-HD-SP-ProgrammingInstructions.txt".

 

- There is no ability to configure connected DxLink receivers from the Web GUI.

- Due to the way many browsers manage file upload requests while in an

  authenticated session, it is not possible to load a DVX setup (.xdv) file

  with any web browser that AMX has tested, except Microsoft Internet Explorer

  when HTTP Security is enabled on the DVX Master.

- IE security does not allow G4WebControl to install by default and

  IE8 64-bit is not supported.

 

----------------------------------------------------------

5. Programming Information

----------------------------------------------------------

------------------- C A U T I O N --------------------------

When upgrading from Master version 4.5.318 or lower, the Switcher must be 

upgraded first before the Master.  Master versions 4.6.319 and later will not 

work with versions of the Switcher older than 1.4.4.


If using a DVX2110-SP (-T) configuration, the Switcher must be running v1.6.31 

or above Switcher firmware. The Master must be running versions 4.8.313 and 

above to use the web configuration page.


If using a DVX3156-SP (-T) configuration, the Switcher must be running v1.6.13 

or above Switcher firmware. The Master must be running versions 4.8.306 and 

above to use the web configuration page.


Before upgrading to version 4.8.316 be sure the DVXX15XHD-XX meets the 

requirements above with regards to the Switcher version. To reduce the 

potential of corrupting firmware; 

1) Flip dipswitch 1 to the up position and reboot the DVXXX15XHD-XX to 

   disable the Netlinx program.

2) Load the SW1905-15_Master_CF_Prep_v4_8_316.kit file and reboot the 

   DVXX15XHD-XX.  


If after upgrading with the prep file (SW1905-15_Master_CF_Prep_v4_8_316.kit), 

still shows the old version number in online tree for the Master firmware

version, then it is likely that the DVXX15XHD-XX does not use a CompactFlash 

for storage.  


Proceed to loading SW1905-15_Master_CF_v4_8_316.kit to complete the upgrade. 

Remember to set dipswitch 1 to the down postion after completing the upgrade

and power cycle the unit.​



Downloads

Product

 

Topic

Firmware

Related Articles

Last modified at 7/2/2020 2:52 PM by PRO Knowledge Base
Top