Configuring Putty for Serial Connection to Soundweb London

Rating
Hardware Requirements

1) Computer with a serial RS232 port or USB-to-Serial adapter.

USB adapters with FTDI chipset or Prolific chipset are recommended.

2) Null modem cable or Null Modem gender changer adapter.
Female 9-pin D-Type to Female 9-pin D-Type where pin 2&3, 4&6, 7&8 are crossed over.


Configuring Putty

The Session options should be configured as below:

Enter Speed: 115200

Set Connection type to: Serial

Enter the COM port used by your serial port.  Check Windows Device Manager for correct COM port number.

 Picture1.png

The Terminal options should be configured as shown below:

Picture2.png 

The Serial options should be configured as shown below:

Picture3.png

This configuration can be saved in the Session options.


Confirming connection

Before you begin, the Soundweb London device should be fully booted.
Click: Open to start the connection.
In the command line window, enter: ?

 Picture4.png

A list of commands will be displayed.  This confirms that the connection is working.

 Picture5.png

 

Troubleshooting

If Putty displays error messages during connection then please check:

1) Serial port or USB adapter:
Ensure that drivers have been installed, if necessary.  Check Windows Device Manager for issues.

2) Cable:
Ensure that cable is wired as Null Modem and terminations are not intermittent. 
Ensure that gender changer adapter is Null Modem type.

3) Do not adjust settings in Windows Device Manager / Ports / Port Settings.

4) Ensure that Soundweb London device is fully booted.

If in doubt, connect to a different Soundweb London device.

 

Commands

The commands used during a serial connection are the same as the Telnet commands.  See Technical Support Guide:  Using Telnet with Soundweb London

​ 