Identifying the Firmware Version in a BSS Soundweb London Device

Rating

​​Firmware in BSS Soundweb London Devices

It is important to determine the firmware version when replacing a Soundweb London device in a working system.  Changing the firmware in a device will cause the devices to mute and stop running its Configuration.  If you load the previous version of firmware back to the device, it will start running its Configuration without the Configuration being uploaded again.  If you change the firmware in a device it will need to be reloaded with the Configuration from the matching version of HiQnet software. 

It is also important to determine the version of the software application which was used to configure and load the Configuration into the devices.  The device firmware version will dictate the version of software that should be used to connect to the system.  

It is not possible to connect to a system with a version of software which is different from the version used to configure the system.  If the version of software installed on the PC is not the same then the firmware in the device may need to be updated and the Configurations will need to be loaded. 


HiQnet Audio Architect

Each version of Audio Architect includes firmware files for all Soundweb London devices.  The firmware files will be specific a number of versions of Audio Architect.  The table in the following guide lists the firmware version associated with each release:  https://help.harmanpro.com/bss-soundweb-london-host-and-dante-firmware-in-hiqnet-audio-architect 

The following guide can be used to identify the version of Audio Architect that was last used to save a Venue file:  Determining the version of HiQnet Audio Architect which was used to save a Venue file​ 

All versions of HiQnet Audio Architect are available to download from the Audio Architect web site here:  https://audioarchitect.harmanpro.com/en-US/softwares/hiqnet-audio-architect-v2-45-2-windows-7-sp1-8-1-10#previous_versions​ 


Displaying Device Firmware Version in Audio Architect

Ensure that the Soundweb London device is connected to the network and discovered in Audio Architect.  Check that Application Options are configured correctly.  The following settings must be enabled: General Settings / Explorer Settings / Display Verbose Device Info in Explorer

1.bmp

Expand the device in the Venue Explorer window.  The firmware version will be displayed in the list of details.  Most Soundweb London firmware versions included in Audio Architect will start with start with the number: 86

2.bmp

The firmware version will also be displayed on the front panel if the device is fitted with an LCD. 

3.jpg


Displaying Device Firmware Versions in London Architect

Ensure that Soundweb London device is connected to the network and discovered in London Architect.  Open the Network window.  Go to the View menu then select:  Network.  Locate the Ethernet folder then left click to select it.  The firmware version will be displayed in the Network Settings window in the field:  Application Version.  The version displayed in the example below relates to London Architect v6.00.R5. 

4.bmp 

The firmware version will also be displayed on the front panel if the device is fitted with an LCD. 

4.jpg


HiQnet London Architect

Each version of London Architect includes firmware files for all Soundweb London devices.  The firmware files will be specific to that version of London Architect.  

Please follow the steps below to identify the version of London Architect that was last used to save a design file. 


  •  Open the file in London Architect
  •  Under View in the Main menu at the top, select:  System Output

The build number will be displayed in the following line:  File last saved in build xxx

5.bmp

The table below lists the software Build Number, software version and associated firmware version.

All versions of HiQnet London Architect are available to download from the BSS Audio web site here:  https://bssaudio.com/en-US/softwares/hiqnet-london-architect-v6-00-r5-windows#previous_versions 

BUILD NUMBER​



​LONDON ARCHITECT VERSION​​​


​​​​BUILD NUMBER​​​​​​​​​​​


​LONDON ARCHITECT VERSION​​

​462​

​​​1.00​​

​​​​​985

​​3.02.R2​​​

​664​​​​

1​​.1
990
​​​3.02.R3

​684​​

1​​.12
1003
​​​3.02.R4

​684​​

1.​​12.R2
1011
​​​3.04

​713​​

​1.1​​4​

1051
​​​3.06
714
1.1​​4.R2
1055

3.06 R2​​​

716
1.1​​4.R2b
1071
​​​​3.08
716

​1.14​​.R3​

1074
​​​3.08 R2
784
2.0​​0.R2
1075
​​​3.08.R3
785
2.0​​0.R3
1078
​​​3.08.R4
786
2.00.​​R4
1117
​​​3.10.R2
801​

​​2​​.02​

1123
​​​3.10.R3
802
2.0​​2.R2
1124​​

​​3.10.R4​​

803
2.0​​2.R3
1144
​​​​3.10.R5
839
2.​​​04
1145
​​​​3.10.R6
840
2.​​04.R2
1146​​​
​​​3.10.R7
841
2​​​​.04.R3
1147​​
​​3.10.R8
846
2.04.R4
1190
​​4.00
876
2.​​06
1192​​
​​4.00.R2
877
2.​​06.R2
1324
​​5.00
878
2.0​​6.R3
1327
​​5.00 R4
888​​
2.0​​6.R4
1328
​​5.00 R5
898
2.06.​​R5
1330
​​​5.02
925
3.​​00
1601
​​​​​6.00
934
3.00​​.R2
1602
​​​6.00 R2
944
3.00​​.R3
1603
​​6.00 R3
951
3.0​​0.R4
1612
​​6.00 R4
955
3.0​​0.R6
1613
​​6.00 R5

​​​959

3.0​​​0.R7

​5019

​​​​​6.02.R3



Downloads

Product

 

Topic

Firmware

Related Articles

Last modified at 9/16/2024 12:25 PM by PRO Knowledge Base
Top