DXLink RX Firmware Update:
Current upgrade version of DXLink RX firmware for non_X00 series.
Release Notes v1.9.73:
DXLink HDMI Receiver Module Firmware
! IMPORTANT: READ PROGRAMMING INFORMATION SECTION BELOW IN
! REGARD TO SPECIAL UPGRADE and DOWNGRADE CONSIDERATIONS
FG#: FG1010-500 (DX-RX, DXLink HDMI Receiver Module)
Release Date: 9/27/2017
Latest Legacy Firmware: v1.9.73
SW1010_500_AVB_KIT_DXLINK_RX_v1_9_73.kit
----------------------------------------------------------
Table of Contents
----------------------------------------------------------
1. Prerequisites
2. Features added in this release
3. Fixes in this release:
4. Notable Points
5. Programming Information
----------------------------------------------------------
----------------------------------------------------------
1. Prerequisites
----------------------------------------------------------
- Directly connected DX-TX should use v1.6.69 (or later).
- Directly connected SDX must use v1.4.9 (or later).
- Legacy Enova DGX 8/16/32/64 must have v2.0.2.2 (or later)
- DVX Switcher Series FW should be v1.6.31 (or later)
- NX Master FW should be v1.4.90 (or later)
- NetLinx Studio v4.3.1519 (or later)
----------------------------------------------------------
2. Features added in this release:
----------------------------------------------------------
- no new features
Includes all features added from versions 1.9.38 to 1.9.69
----------------------------------------------------------
3. Fixes in this release:
----------------------------------------------------------
- Fixed issue to allow multiple vendors of SPI Flash
Includes all fixes made from versions 1.9.38 to 1.9.69
! IMPORTANT: Version 1.9.73 is essentially the same as
! 1.9.69 BUT it allows a new factory unit to be downgraded
! to a legacy version that includes all latest
hotfixes.
! A new factory RX with 1.13.43 cannot be downgraded to any
! legacy version ealier than 1.9.73
----------------------------------------------------------
4. Notable Points
----------------------------------------------------------
- If a send command "FACTORYAV" or telnet
"RESET FACTORY"
is sent, a reboot of
the RX will be required.
- PLEASE READ the documentation in regard to the DIP
switches located on
the bottom of the Tx/Rx modules
before attempting to
connect to the network
- The RX uses a solid ORANGE screen to indicate an HDCP
authentication
failure with the connected device
- If using a hostname in the USB_HID_ROUTE command, the
hostname length is
limited to 50 characters
----------------------------------------------------------
5. Programming Information
----------------------------------------------------------
- Downgrade Note: Due to a HW ID change, RXs with a factory
firmware image of
v1.13.43 or later will not downgrade
to a 100 series
version earlier than v1.13.43 OR a legacy
version earlier than
v1.9.73
- To see what factory image is loaded, open a telnet
session to the RX
and type: fwimages - The version
shown in slot 0 is
the factory version.
- Due to a previous FPGA change in a legacy 1.9.x version,
this kit may fail on
the first firmware transfer attempt
if upgrading from
version earlier than v1.9.32. If it
does, reboot the RX
and send this kit again.